# ESPectre (Francesco Pace) — Technique Reference
|
||
|
||
Source: *How I Turned My Wi-Fi Into a Motion Sensor — Part 2*
|
||
(Dec 2025), Medium / [francescopace/espectre](https://github.com/francescopace/espectre)
|
||
on GitHub, GPLv3.
|
||
|
||
Captures the three core techniques and the support tooling Pace
|
||
shipped. RuView has adopted some, partially adopted others, and not
|
||
adopted the rest. This doc is a living checklist — update when items
|
||
move.
|
||
|
||
## 1. Gain Lock (AGC + FFT scale)
|
||
|
||
The ESP32 PHY applies automatic gain control per packet. For normal
|
||
WiFi reception that keeps decoding optimal; for CSI sensing it
|
||
manifests as a 20-30 % slow drift in amplitude even in an empty
|
||
room, masking real body modulation. Two undocumented PHY routines
|
||
freeze the gain:
|
||
|
||
```c
|
||
extern void phy_fft_scale_force(bool force_en, int8_t force_value);
|
||
extern void phy_force_rx_gain(int force_en, int force_value);
|
||
```
|
||
|
||
Recipe:
|
||
|
||
1. After WiFi association, collect AGC and FFT gain values from
|
||
each CSI packet.
|
||
2. At packet 300 (~3 s at 100 pps), take the **median** of each
|
||
(more robust than mean against outliers).
|
||
3. Call the two PHY routines with the medians to lock the radio.
|
||
4. Safety branch: if median AGC < 30, skip the lock — forcing low
|
||
gain freezes the RX path. Sensor must be moved further from AP.
|
||
|
||
Supported targets: ESP32-S3, ESP32-C3, ESP32-C5, ESP32-C6. Older
|
||
parts have no access to these PHY hooks.
|
||
|
||
**RuView status — DONE.** ADR-100 (commit `8aef8206`).
|
||
Implemented in `firmware/esp32-csi-node/main/csi_collector.c` as
|
||
`rv_gain_lock_process`. Boot log on both sensors:
|
||
`gain-lock APPLIED: AGC=42/44, FFT=-31/-42 (median of 300 packets)`.
|
||
Empty-room CV dropped from ~10 % (full broadband) to 3-4 % after
|
||
NBVI also kicked in.
|
||
|
||
## 2. NBVI — Normalized Baseline Variability Index
|
||
|
||
Per-subcarrier score that picks the K most useful subcarriers
|
||
automatically.
|
||
|
||
```
|
||
NBVI(k) = α · (σ_k / μ_k²) + (1 - α) · (σ_k / μ_k), α = 0.5
|
||
```
|
||
|
||
* `σ_k / μ_k²` penalises weak subcarriers (low μ → high score → bad).
|
||
* `σ_k / μ_k` is the standard coefficient of variation; rewards
|
||
stability.
|
||
* α = 0.5 balances; pure σ/μ² picks stable-but-quiet bins, pure σ/μ
|
||
picks loud-but-noisy bins.
|
||
* Amplitude-only (no phase) — phase has Temporal Phase Rotation
|
||
artefacts that need extra calibration; amplitude is calibration-
|
||
free.
|
||
|
||
Four-step pipeline at boot:
|
||
|
||
| Step | What | Detail |
|
||
|---|---|---|
|
||
| 1 | **Find quiet moments** | Slide a window across the calibration buffer, pick the windows with the lowest aggregate variance via percentile detection. Tolerates someone walking through during boot. |
|
||
| 2 | **Dead-zone gate** | Drop any subcarrier with mean amplitude below the 25th percentile across all subcarriers. Guard tones + null bins are excluded so they don't "win" σ/μ² → ∞. |
|
||
| 3 | **Rank + validate** | Sort by NBVI ascending. Run the motion detector on each candidate config, measure false-positive rate, take the config with the lowest FP. |
|
||
| 4 | **Pick winners** | Top-K by lowest NBVI (typically K = 12 for HT20). |
|
||
|
||
Memory: O(N) running with on-the-fly mean/variance updates ⇒ ≈ 256 B
|
||
for 64 subcarriers. Time: O(N · L) per recompute, milliseconds on a
|
||
$10 device.
|
||
|
||
**RuView status — PARTIALLY DONE.** ADR-102 (commit `2f12a223`).
|
||
Server-side port in `amp_presence_override` /
|
||
`nbvi_select_top_k`. What we have:
|
||
|
||
- ✅ NBVI formula with α = 0.5
|
||
- ✅ Top-12 selection
|
||
- ✅ Dead-zone gate (`NBVI_DEAD_GATE_PCT = 0.25`)
|
||
- ✅ Recompute throttled (`NBVI_REFRESH_TICKS = 200` ≈ every 5 s)
|
||
|
||
What we **do not** have:
|
||
|
||
- ❌ **Step 1 quiet-window finder** — we use the *whole* history
|
||
buffer. If the buffer captures someone moving, ranking is biased.
|
||
Pace's percentile-window detector should be added.
|
||
- ❌ **Step 3 FP-rate validation** — we accept the raw NBVI ranking
|
||
without testing it on the calibration data.
|
||
- ❌ **Boot calibration sequence** (FW-side, 7 s post gain-lock).
|
||
Ours is server-side rolling, which means selection drifts forever
|
||
rather than locking after boot. Trade-off: adapts to room
|
||
rearrangement, but never "settles".
|
||
|
||
Empirically on the operator's deployment NBVI alone gave a 1.5-2× CV
|
||
reduction:
|
||
|
||
| | Full 56 subc | NBVI top-12 |
|
||
|---|---|---|
|
||
| node 1 idle CV | 5.0 % | 3.1 % |
|
||
| node 2 idle CV | 7.0 % | 3.9 % |
|
||
|
||
## 3. Baseline-variance threshold normalization
|
||
|
||
Pace's third problem was that `threshold = 1.0` meant different
|
||
things on different devices. Fix:
|
||
|
||
```python
|
||
if baseline_variance > 0.25:
|
||
scale = 0.25 / baseline_variance
|
||
else:
|
||
scale = 1.0
|
||
```
|
||
|
||
Reference 0.25 is what a quiet room typically measures during NBVI
|
||
calibration. Apply the scale to the live motion score, so the user-
|
||
facing threshold (`= 1.0`) is universal across rooms.
|
||
|
||
**RuView status — NOT DONE.** Our `amp_node_level` uses fixed
|
||
thresholds tuned to one deployment (CV 10 % moving, CV 22 % active,
|
||
mean/baseline < 0.75 still). Other deployments will need re-tuning.
|
||
|
||
## 4. Two-phase boot calibration
|
||
|
||
```
|
||
PHASE 1: GAIN LOCK (3 s, 300 packets)
|
||
Collect AGC/FFT → median → lock.
|
||
PHASE 2: NBVI CALIBRATION (7 s, 700 packets)
|
||
With gain locked, rank subcarriers → pick top-K.
|
||
Total ≈ 10 s. Room must be mostly quiet during this window.
|
||
```
|
||
|
||
**RuView status — SPLIT.** Phase 1 is in FW (ADR-100). Phase 2 lives
|
||
in the server as a rolling refresh, not a boot-time fix-point. See
|
||
NBVI section above for the implications.
|
||
|
||
## 5. Persisted baseline / device threshold
|
||
|
||
After NBVI calibration, ESPectre writes the AGC/FFT lock values, the
|
||
chosen subcarrier set, the baseline variance, and the threshold into
|
||
NVS so reboots don't need re-calibration.
|
||
|
||
**RuView status — NOT DONE.** Each server restart triggers a fresh
|
||
60-second baseline learn. NBVI also re-ranks from scratch on restart.
|
||
Open item: persist `AMP_LATEST.baseline` to disk + load at startup.
|
||
|
||
## 6. Interactive Web Serial game (`espectre.dev/game`)
|
||
|
||
Browser ↔ ESP32 over USB Web Serial API. Shows live motion as a bar,
|
||
lets user tune `threshold` while playing a reaction game. Settings
|
||
persist via NVS.
|
||
|
||
**RuView status — NOT DONE.** Closest analogue is our `raw.html`
|
||
calibration console (per-node bars + RSSI trace), but it's read-only.
|
||
|
||
## 7. Native Home Assistant integration via ESPHome
|
||
|
||
Sensor exposes occupancy/motion entities directly to HA.
|
||
|
||
**RuView status — NOT DONE.** No HA integration path. Could be added
|
||
via MQTT or a custom ESPHome component.
|
||
|
||
## 8. Test suite
|
||
|
||
Pace ships 500+ unit tests, 90 % coverage, validated against a fixed
|
||
2000-packet capture (1000 idle + 1000 motion). CI runs PlatformIO,
|
||
pytest, ESPHome build, Codecov on every push.
|
||
|
||
**RuView status — PARTIAL.** Agent added 2 regression tests for the
|
||
binary CSI frame parser (`csi.rs:751`); no regression set captured
|
||
for the amplitude classifier or NBVI.
|
||
|
||
## Comparison summary (what RuView has, doesn't have, has differently)
|
||
|
||
| Item | Pace / ESPectre | RuView |
|
||
|---|---|---|
|
||
| Gain lock | FW, 300 pkt median, AGC+FFT, AGC<30 skip | ✅ Same, in `csi_collector.c` |
|
||
| NBVI formula | α·σ/μ² + (1-α)·σ/μ, α=0.5, top-12 | ✅ Same, server-side |
|
||
| Dead-zone gate | 25th percentile of mean | ✅ `NBVI_DEAD_GATE_PCT=0.25` |
|
||
| Quiet-window finder | Percentile-window in calibration buffer | ❌ Use full window verbatim |
|
||
| FP-rate validation of NBVI pick | Yes | ❌ Take raw ranking |
|
||
| Boot-time NBVI freeze | FW, ~7 s post-lock | ❌ Server-side rolling |
|
||
| Baseline variance normalization | `scale = 0.25 / σ²` | ❌ Fixed thresholds per deployment |
|
||
| NVS persistence of calibration | Yes | ❌ Fresh learn each restart |
|
||
| Universal threshold | One value across rooms | ❌ Re-tune per deployment |
|
||
| Calibration UI | Web Serial game | ❌ Read-only raw.html |
|
||
| HA integration | ESPHome native | ❌ None |
|
||
| Test suite | 500+ tests, 90 % coverage | ❌ ~2 parser tests only |
|
||
| Phase / amplitude | Amplitude only (TPR avoidance) | ✅ Same |
|
||
| Subcarrier count | 64 (HT20) | 56 (ESP32-S3 reports 56 non-guard) |
|
||
|
||
## Open items, ranked by expected impact on RuView
|
||
|
||
1. **Quiet-window finder for NBVI Step 1** — if the operator restarts
|
||
the server while the room is occupied, current NBVI biases its
|
||
ranking toward subcarriers stable on the *occupied* state. Bug:
|
||
present_still then under-triggers. ~1 h.
|
||
2. **Persist `AMP_LATEST.baseline` to disk** — eliminates the
|
||
"step outside for 60 s" ritual after every restart. ~30 min.
|
||
3. **Baseline variance normalization** — would let us ship one
|
||
threshold set for any deployment. ~1 h.
|
||
4. **FP-rate validation of NBVI pick** — would catch the case where
|
||
the top-12 ranked subcarriers happen to overlap with a noise
|
||
source. ~1 h.
|
||
5. **Boot-time NBVI freeze** — if we want fully reproducible
|
||
behaviour. Trade-off: doesn't adapt to room changes. ~2 h.
|
||
6. **HA / ESPHome integration** — depends on whether RuView wants
|
||
to be a HA sensor or stay standalone. ~1 day.
|
||
7. **Web Serial calibration UI** — nice-to-have, lower priority than
|
||
the algorithmic items. ~1 day.
|