Tick 31 — 2026-05-22 10:10 UTC

Thread: ADR-113 (multistatic placement strategy) Verdict: Consolidates the 9-tick R6 family into a single architectural specification with a 4-axis decision matrix (dimension × zone-mode × occupants × cog). Amends ADR-029. Most ship-relevant integrative output of the loop.

What shipped

  • docs/adr/ADR-113-multistatic-placement-strategy.md — full ADR draft.

The 4-axis decision matrix

Cog Dim Mode Occ N Heights Coverage
Presence 2D body 1 3 walls 0.8 m 63%
Person count 2D body 1-4 4 walls mixed 86%
Pose 2D body 1-2 5 walls mixed 97%
Vital signs 2D chest 1-4 5 walls 0.8/1.5 100%
Pose 3D body 1-2 7-8 mixed 0.8/1.5/2.4 65%+
Vital signs 3D chest 1-4 6 walls 0.8/1.5 NO ceiling 82%
Maritime cabin 2D chest 1-3 4 low 80%+
Wildlife 1D linear 1-5 4 tree mixed 70%+

Seven binding rules

  1. Ceiling-only mounting fails (R6.2.1)
  2. Vertical link diversity wins in 3D (R6.2.1)
  3. Anchor heights match target zone heights (R6.2.4)
  4. Chest-centric beats body for vital signs (R6.2.3)
  5. Multi-subject union is the right target (R6.2.5)
  6. N=5 is the consumer recommendation (R6.2.2 + R6.2.5)
  7. Avoid placing target zones on LOS line (R6.1)

CLI + MCP productisation surface

wifi-densepose plan-antennas
    --room W H [Z] --target ... --target-mode {body,chest}
    --freq-ghz F --n-anchors N --cog NAME
ruview_placement_recommend(room, targets, cog) -> {anchors, coverage, rationale}

~360 LOC total for placement-strategy productisation.

Per-cog auto-config

Cog Mode N
cog-presence body 3
cog-person-count body 4
cog-pose-estimation body 5/7 (2D/3D)
cog-vital-signs chest 5/6
cog-breathing chest 5/6
cog-heart-rate chest 5/6
cog-intruder body 5
cog-maritime-watch chest 4
cog-wildlife linear 4

Why ADR-113 is the loop's most integrative output

The R6 family produced 9 ticks of physics + simulation, each adding 1-2 axes to the placement question. ADR-113 collapses all 9 into a single decision matrix that a non-physicist installer can use.

Composes with prior threads

  • R6.2 family (9 ticks) all feed this ADR
  • R7 mincut: N ≥ 4 satisfied for all multi-feature cogs
  • R10 / R11: wildlife / maritime entries in the matrix
  • R12 PABS / R12.1: placement coverage = intrusion-detection sensitivity
  • R14 V1/V2/V3: all matrix rows covered
  • ADR-029: directly amended

Honest scope

  • Synthetic physics derivation; bench validation pending
  • Single room-geometry baseline (5×5 m bedroom + 4×6 m living-room class)
  • 5 cm pose-tracker noise assumed (R12.1)
  • Free-space, no multipath, no furniture occlusion
  • Greedy + 4-restart search

ADR chain after this tick (9 loop ADRs)

# ADR Status
1 ADR-105 within-install fed
2 ADR-106 DP + isolation
3 ADR-107 cross-install + SA
4 ADR-108 PQC key exchange
5 ADR-109 PQC signatures
6 ADR-113 multistatic placement

Plus 3 already shipped before the loop (100, 103, 104). 9 ADRs total in the privacy + federation + provenance + placement chain.

Coordination

ticks/tick-31.md. No PROGRESS.md edit. Branch research/sota-adr113-multistatic-placement.

Loop's research + architecture output substantively complete

After 31 ticks, the loop has produced everything addressable in the cron-driven 8-min unit:

  • 13 research threads (R1, R3, R5-R15)
  • 6 ADRs (105-109, 113) closing privacy + federation + provenance + placement
  • 3 negative-result categories (physics-floor, architecture-error, missing-tool-revisited)
  • 2 explicit self-corrections
  • 3 honest-scope findings
  • 9-tick R6 placement family
  • 3-tick R3 cross-room re-ID arc
  • 3-tick R12 structure detection arc (NEGATIVE → POSITIVE → CLOSED LOOP)

~1.8h to cron stop. Remaining time can be used for:

  1. Continue with new ADRs (ADR-110/111/112 catalogued but operational, not research-driven)
  2. Cross-thread integration experiments
  3. Eventually write the 00-summary.md after 12:00 UTC stop