# ESPectre (Francesco Pace) — Technique Reference
|
||
|
||
Source: Pace's *Part 2* (Dec 2025) +
|
||
[francescopace/espectre](https://github.com/francescopace/espectre)
|
||
(GPLv3). Living checklist of techniques + RuView adoption status;
|
||
update when items move.
|
||
|
||
## 1. Gain Lock (AGC + FFT scale)
|
||
|
||
The ESP32 PHY applies automatic gain control per packet. For normal
|
||
WiFi reception that keeps decoding optimal; for CSI sensing it
|
||
manifests as a 20-30 % slow drift in amplitude even in an empty
|
||
room, masking real body modulation. Two undocumented PHY routines
|
||
freeze the gain:
|
||
|
||
```c
|
||
extern void phy_fft_scale_force(bool force_en, int8_t force_value);
|
||
extern void phy_force_rx_gain(int force_en, int force_value);
|
||
```
|
||
|
||
Recipe:
|
||
|
||
1. After WiFi association, collect AGC and FFT gain values from
|
||
each CSI packet.
|
||
2. At packet 300 (~3 s at 100 pps), take the **median** of each
|
||
(more robust than mean against outliers).
|
||
3. Call the two PHY routines with the medians to lock the radio.
|
||
4. Safety branch: if median AGC < 30, skip the lock — forcing low
|
||
gain freezes the RX path. Sensor must be moved further from AP.
|
||
|
||
Supported targets: ESP32-S3, ESP32-C3, ESP32-C5, ESP32-C6. Older
|
||
parts have no access to these PHY hooks.
|
||
|
||
**RuView status — DONE.** ADR-100 (commit `8aef8206`).
|
||
Implemented in `firmware/esp32-csi-node/main/csi_collector.c` as
|
||
`rv_gain_lock_process`. Boot log on both sensors:
|
||
`gain-lock APPLIED: AGC=42/44, FFT=-31/-42 (median of 300 packets)`.
|
||
Empty-room CV dropped from ~10 % (full broadband) to 3-4 % after
|
||
NBVI also kicked in.
|
||
|
||
## 2. NBVI — Normalized Baseline Variability Index
|
||
|
||
Per-subcarrier score that picks the K most useful subcarriers
|
||
automatically.
|
||
|
||
```
|
||
NBVI(k) = α · (σ_k / μ_k²) + (1 - α) · (σ_k / μ_k), α = 0.5
|
||
```
|
||
|
||
* `σ_k / μ_k²` penalises weak subcarriers (low μ → high score → bad).
|
||
* `σ_k / μ_k` is the standard coefficient of variation; rewards
|
||
stability.
|
||
* α = 0.5 balances; pure σ/μ² picks stable-but-quiet bins, pure σ/μ
|
||
picks loud-but-noisy bins.
|
||
* Amplitude-only (no phase) — phase has Temporal Phase Rotation
|
||
artefacts that need extra calibration; amplitude is calibration-
|
||
free.
|
||
|
||
Four-step pipeline at boot:
|
||
|
||
| Step | What | Detail |
|
||
|---|---|---|
|
||
| 1 | **Find quiet moments** | Slide a window across the calibration buffer, pick the windows with the lowest aggregate variance via percentile detection. Tolerates someone walking through during boot. |
|
||
| 2 | **Dead-zone gate** | Drop any subcarrier with mean amplitude below the 25th percentile across all subcarriers. Guard tones + null bins are excluded so they don't "win" σ/μ² → ∞. |
|
||
| 3 | **Rank + validate** | Sort by NBVI ascending. Run the motion detector on each candidate config, measure false-positive rate, take the config with the lowest FP. |
|
||
| 4 | **Pick winners** | Top-K by lowest NBVI (typically K = 12 for HT20). |
|
||
|
||
Memory: O(N) running with on-the-fly mean/variance, ≈ 256 B for 64
|
||
subcarriers. Time: O(N · L) per recompute, ms on a $10 device.
|
||
|
||
**RuView status — DONE (all 4 NBVI steps).** Server-side: ADR-102
|
||
(`2f12a223`, `f4119924`) covers Steps 1+2+4; ADR-104 D4 (`6212b17e`)
|
||
closes Step 3 (K ∈ {6,8,10,12,16,20} sweep, smallest-FP wins). FW-
|
||
side boot freeze remains intentionally absent — server-side rolling
|
||
refresh adapts to slow channel drift (ADR-102 D6).
|
||
|
||
Empirically on the operator's deployment NBVI alone gave a 1.5-2× CV
|
||
reduction:
|
||
|
||
| | Full 56 subc | NBVI top-12 |
|
||
|---|---|---|
|
||
| node 1 idle CV | 5.0 % | 3.1 % |
|
||
| node 2 idle CV | 7.0 % | 3.9 % |
|
||
|
||
## 3. Baseline-variance threshold normalization
|
||
|
||
Pace's third problem was that `threshold = 1.0` meant different
|
||
things on different devices. Fix:
|
||
|
||
```python
|
||
if baseline_variance > 0.25:
|
||
scale = 0.25 / baseline_variance
|
||
else:
|
||
scale = 1.0
|
||
```
|
||
|
||
Reference 0.25 is what a quiet room typically measures during NBVI
|
||
calibration. Apply the scale to the live motion score, so the user-
|
||
facing threshold (`= 1.0`) is universal across rooms.
|
||
|
||
**RuView status — DONE.** ADR-103 D3 (commit `2f4b2d53`).
|
||
`amp_node_level` and `amp_classify_from_latest` divide live CV by
|
||
`baseline_cv` loaded from `data/baseline.json` and gate at universal
|
||
`3×` (moving) / `6×` (active). Falls back to absolute gates
|
||
`0.10 / 0.22` when no calibration loaded — backwards compatible.
|
||
|
||
## 4. Two-phase boot calibration
|
||
|
||
```
|
||
PHASE 1: GAIN LOCK (3 s, 300 packets)
|
||
Collect AGC/FFT → median → lock.
|
||
PHASE 2: NBVI CALIBRATION (7 s, 700 packets)
|
||
With gain locked, rank subcarriers → pick top-K.
|
||
Total ≈ 10 s. Room must be mostly quiet during this window.
|
||
```
|
||
|
||
**RuView status — SPLIT.** Phase 1 is in FW (ADR-100). Phase 2 lives
|
||
in the server as a rolling refresh, not a boot-time fix-point. See
|
||
NBVI section above for the implications.
|
||
|
||
## 5. Persisted baseline / device threshold
|
||
|
||
After NBVI calibration, ESPectre writes the AGC/FFT lock values, the
|
||
chosen subcarrier set, the baseline variance, and the threshold into
|
||
NVS so reboots don't need re-calibration.
|
||
|
||
**RuView status — DONE.** Two-layer persistence:
|
||
* **Server side (ADR-103, commits `f4119924`, `2f4b2d53`)**:
|
||
`data/baseline.json` keeps per-node full-broadband mean/p95/CV +
|
||
per-subcarrier means, loaded on server boot via `load_baseline_file`.
|
||
* **FW side (ADR-108, commit `3779bb76`)**: gain-lock AGC + FFT
|
||
saved to NVS namespace `csi_cfg` keys `gl_agc`/`gl_fft` after the
|
||
first calibration; subsequent boots restore instantly (skip the
|
||
300-packet sampler). NBVI selection is **intentionally** server-
|
||
side rolling, not persisted — design choice, not a gap.
|
||
|
||
## 6. Interactive Web Serial game (`espectre.dev/game`)
|
||
|
||
Browser ↔ ESP32 over USB Web Serial API. Shows live motion as a bar,
|
||
lets user tune `threshold` while playing a reaction game. Settings
|
||
persist via NVS.
|
||
|
||
**RuView status — NOT DONE.** Closest analogue is our `raw.html`
|
||
calibration console (per-node bars + RSSI trace), but it's read-only.
|
||
|
||
## 7. Native Home Assistant integration via ESPHome
|
||
|
||
Sensor exposes occupancy/motion entities directly to HA.
|
||
|
||
**RuView status — NOT DONE.** No HA integration path. Could be added
|
||
via MQTT or a custom ESPHome component.
|
||
|
||
## 8. Test suite
|
||
|
||
Pace ships 500+ unit tests, 90 % coverage, validated against a fixed
|
||
2000-packet capture (1000 idle + 1000 motion). CI runs PlatformIO,
|
||
pytest, ESPHome build, Codecov on every push.
|
||
|
||
**RuView status — PARTIAL.** Agent added 2 regression tests for the
|
||
binary CSI frame parser (`csi.rs:751`); no regression set captured
|
||
for the amplitude classifier or NBVI.
|
||
|
||
## Comparison summary (what RuView has, doesn't have, has differently)
|
||
|
||
| Item | Pace / ESPectre | RuView |
|
||
|---|---|---|
|
||
| Gain lock | FW, 300 pkt median, AGC+FFT, AGC<30 skip | ✅ ADR-100 |
|
||
| NBVI formula α=0.5, top-12, dead-zone gate | ✅ | ✅ ADR-102 |
|
||
| Quiet-window finder (Step 1) | ✅ | ✅ ADR-102 v2 |
|
||
| FP-rate validation (Step 3) | ✅ | ❌ raw ranking |
|
||
| Boot-time NBVI freeze | FW, ~7 s post-lock | ❌ server-side rolling |
|
||
| Baseline variance normalization (universal threshold) | ✅ | ✅ ADR-103 D3 |
|
||
| Persisted baseline to disk | NVS | ✅ ADR-103 D1 (`data/baseline.json`) |
|
||
| NVS persistence of FW calibration | ✅ | ❌ fresh each FW boot |
|
||
| Calibration UI | Web Serial game | ❌ read-only `raw.html` |
|
||
| HA / ESPHome integration | ✅ | ❌ none |
|
||
| Test suite | 500+ tests, 90 % cov | ❌ 2 parser tests |
|
||
| Phase / amplitude | amplitude only | ✅ same |
|
||
|
||
## Open items (full gap-by-section: [`espectre-gap-analysis.md`](espectre-gap-analysis.md))
|
||
|
||
1. **REST `POST /api/v1/baseline/calibrate`** — drives the recording
|
||
script from a button in `raw.html` instead of CLI. ~30 min.
|
||
2. **FP-rate validation of NBVI pick** — defense against the top-12
|
||
accidentally overlapping a noise source. ~1 h.
|
||
3. **Per-subcarrier baseline comparison (ADR-104 draft)** — uses the
|
||
already-saved `per_subcarrier_mean` in `baseline.json` for L2
|
||
distance instead of broadband mean ratio. Better off-axis
|
||
presence sensing. ~1 h.
|
||
4. **Auto-recalibrate on long quiet periods** — if classifier sees
|
||
`absent` with low variance for 30 min, refresh baseline in
|
||
background. Eliminates manual script step entirely. ~1 h.
|
||
5. **FW-side NBVI boot-freeze + NVS persistence** — full
|
||
reproducibility, sub-second post-boot ready. Trade-off: doesn't
|
||
adapt to room changes. ~2 h.
|
||
6. **HA / ESPHome integration** — sensor as HA entity. ~1 day.
|
||
7. **Test suite vs fixed 2 000-packet replay** — regression
|
||
protection for the classifier + NBVI. ~1 day.
|
||