ESPectre (Francesco Pace) — Technique Reference
Source: How I Turned My Wi-Fi Into a Motion Sensor — Part 2 (Dec 2025), Medium / francescopace/espectre on GitHub, GPLv3.
Captures the three core techniques and the support tooling Pace shipped. RuView has adopted some, partially adopted others, and not adopted the rest. This doc is a living checklist — update when items move.
1. Gain Lock (AGC + FFT scale)
The ESP32 PHY applies automatic gain control per packet. For normal WiFi reception that keeps decoding optimal; for CSI sensing it manifests as a 20-30 % slow drift in amplitude even in an empty room, masking real body modulation. Two undocumented PHY routines freeze the gain:
extern void phy_fft_scale_force(bool force_en, int8_t force_value);
extern void phy_force_rx_gain(int force_en, int force_value);
Recipe:
- After WiFi association, collect AGC and FFT gain values from each CSI packet.
- At packet 300 (~3 s at 100 pps), take the median of each (more robust than mean against outliers).
- Call the two PHY routines with the medians to lock the radio.
- Safety branch: if median AGC < 30, skip the lock — forcing low gain freezes the RX path. Sensor must be moved further from AP.
Supported targets: ESP32-S3, ESP32-C3, ESP32-C5, ESP32-C6. Older parts have no access to these PHY hooks.
RuView status — DONE. ADR-100 (commit 8aef8206).
Implemented in firmware/esp32-csi-node/main/csi_collector.c as
rv_gain_lock_process. Boot log on both sensors:
gain-lock APPLIED: AGC=42/44, FFT=-31/-42 (median of 300 packets).
Empty-room CV dropped from ~10 % (full broadband) to 3-4 % after
NBVI also kicked in.
2. NBVI — Normalized Baseline Variability Index
Per-subcarrier score that picks the K most useful subcarriers automatically.
NBVI(k) = α · (σ_k / μ_k²) + (1 - α) · (σ_k / μ_k), α = 0.5
σ_k / μ_k²penalises weak subcarriers (low μ → high score → bad).σ_k / μ_kis the standard coefficient of variation; rewards stability.- α = 0.5 balances; pure σ/μ² picks stable-but-quiet bins, pure σ/μ picks loud-but-noisy bins.
- Amplitude-only (no phase) — phase has Temporal Phase Rotation artefacts that need extra calibration; amplitude is calibration- free.
Four-step pipeline at boot:
| Step | What | Detail |
|---|---|---|
| 1 | Find quiet moments | Slide a window across the calibration buffer, pick the windows with the lowest aggregate variance via percentile detection. Tolerates someone walking through during boot. |
| 2 | Dead-zone gate | Drop any subcarrier with mean amplitude below the 25th percentile across all subcarriers. Guard tones + null bins are excluded so they don't "win" σ/μ² → ∞. |
| 3 | Rank + validate | Sort by NBVI ascending. Run the motion detector on each candidate config, measure false-positive rate, take the config with the lowest FP. |
| 4 | Pick winners | Top-K by lowest NBVI (typically K = 12 for HT20). |
Memory: O(N) running with on-the-fly mean/variance, ≈ 256 B for 64 subcarriers. Time: O(N · L) per recompute, ms on a $10 device.
RuView status — DONE (Steps 1, 2, 4). ADR-102 (commits
2f12a223 + f4119924). Server-side, see ADR-102 for detail.
Missing: ❌ Step 3 FP-rate validation, ❌ FW-side boot freeze.
Empirically on the operator's deployment NBVI alone gave a 1.5-2× CV reduction:
| Full 56 subc | NBVI top-12 | |
|---|---|---|
| node 1 idle CV | 5.0 % | 3.1 % |
| node 2 idle CV | 7.0 % | 3.9 % |
3. Baseline-variance threshold normalization
Pace's third problem was that threshold = 1.0 meant different
things on different devices. Fix:
if baseline_variance > 0.25:
scale = 0.25 / baseline_variance
else:
scale = 1.0
Reference 0.25 is what a quiet room typically measures during NBVI
calibration. Apply the scale to the live motion score, so the user-
facing threshold (= 1.0) is universal across rooms.
RuView status — DONE. ADR-103 D3 (commit 2f4b2d53).
amp_node_level and amp_classify_from_latest divide live CV by
baseline_cv loaded from data/baseline.json and gate at universal
3× (moving) / 6× (active). Falls back to absolute gates
0.10 / 0.22 when no calibration loaded — backwards compatible.
4. Two-phase boot calibration
PHASE 1: GAIN LOCK (3 s, 300 packets)
Collect AGC/FFT → median → lock.
PHASE 2: NBVI CALIBRATION (7 s, 700 packets)
With gain locked, rank subcarriers → pick top-K.
Total ≈ 10 s. Room must be mostly quiet during this window.
RuView status — SPLIT. Phase 1 is in FW (ADR-100). Phase 2 lives in the server as a rolling refresh, not a boot-time fix-point. See NBVI section above for the implications.
5. Persisted baseline / device threshold
After NBVI calibration, ESPectre writes the AGC/FFT lock values, the chosen subcarrier set, the baseline variance, and the threshold into NVS so reboots don't need re-calibration.
RuView status — DONE for baseline; PARTIAL for the rest. ADR-103
(commits f4119924, 2f4b2d53). data/baseline.json persists per-
node full-broadband mean/p95/CV + per-subcarrier means, loaded at
server boot via load_baseline_file. Gain lock + NBVI selection
still happen fresh on each FW boot / server boot respectively (open
items 4 + 5 below).
6. Interactive Web Serial game (espectre.dev/game)
Browser ↔ ESP32 over USB Web Serial API. Shows live motion as a bar,
lets user tune threshold while playing a reaction game. Settings
persist via NVS.
RuView status — NOT DONE. Closest analogue is our raw.html
calibration console (per-node bars + RSSI trace), but it's read-only.
7. Native Home Assistant integration via ESPHome
Sensor exposes occupancy/motion entities directly to HA.
RuView status — NOT DONE. No HA integration path. Could be added via MQTT or a custom ESPHome component.
8. Test suite
Pace ships 500+ unit tests, 90 % coverage, validated against a fixed 2000-packet capture (1000 idle + 1000 motion). CI runs PlatformIO, pytest, ESPHome build, Codecov on every push.
RuView status — PARTIAL. Agent added 2 regression tests for the
binary CSI frame parser (csi.rs:751); no regression set captured
for the amplitude classifier or NBVI.
Comparison summary (what RuView has, doesn't have, has differently)
| Item | Pace / ESPectre | RuView |
|---|---|---|
| Gain lock | FW, 300 pkt median, AGC+FFT, AGC<30 skip | ✅ ADR-100 |
| NBVI formula α=0.5, top-12, dead-zone gate | ✅ | ✅ ADR-102 |
| Quiet-window finder (Step 1) | ✅ | ✅ ADR-102 v2 |
| FP-rate validation (Step 3) | ✅ | ❌ raw ranking |
| Boot-time NBVI freeze | FW, ~7 s post-lock | ❌ server-side rolling |
| Baseline variance normalization (universal threshold) | ✅ | ✅ ADR-103 D3 |
| Persisted baseline to disk | NVS | ✅ ADR-103 D1 (data/baseline.json) |
| NVS persistence of FW calibration | ✅ | ❌ fresh each FW boot |
| Calibration UI | Web Serial game | ❌ read-only raw.html |
| HA / ESPHome integration | ✅ | ❌ none |
| Test suite | 500+ tests, 90 % cov | ❌ 2 parser tests |
| Phase / amplitude | amplitude only | ✅ same |
Open items, ranked by expected impact on RuView
- REST
POST /api/v1/baseline/calibrate— drives the recording script from a button inraw.htmlinstead of CLI. ~30 min. - FP-rate validation of NBVI pick — defense against the top-12 accidentally overlapping a noise source. ~1 h.
- Per-subcarrier baseline comparison (ADR-104 draft) — uses the
already-saved
per_subcarrier_meaninbaseline.jsonfor L2 distance instead of broadband mean ratio. Better off-axis presence sensing. ~1 h. - Auto-recalibrate on long quiet periods — if classifier sees
absentwith low variance for 30 min, refresh baseline in background. Eliminates manual script step entirely. ~1 h. - FW-side NBVI boot-freeze + NVS persistence — full reproducibility, sub-second post-boot ready. Trade-off: doesn't adapt to room changes. ~2 h.
- HA / ESPHome integration — sensor as HA entity. ~1 day.
- Test suite vs fixed 2 000-packet replay — regression protection for the classifier + NBVI. ~1 day.
- Web Serial calibration game — nice-to-have. ~1 day.