UI side of ADR-107: green "calibrate empty" button in raw.html next
to the existing reset/log-y controls. Click → confirm dialog tells
the operator to step out → POST /api/v1/baseline/calibrate with
90 s capture window → polls GET /api/v1/baseline every 2 s, surfaces
"recording… N/90 s" then "baseline updated ✓".
ADR-107 documents:
D1 in-process capture_baseline_to_disk (port of record-baseline.py)
D2 BASELINE_BUS broadcast forwarder so capture stays decoupled from
WS clients
D3 POST /api/v1/baseline/calibrate (immediate ack, background work)
D4 GET /api/v1/baseline (current state + cooldown + status)
D5 auto_recalibrate_task — 30-min absent+low-CV trigger, 1-h cooldown
D6 raw.html button + polling
|
||
|---|---|---|
| .. | ||