{ "model": "PTT + pulse-contour physics scrutiny for contactless BP", "ptt": { "baseline_ms": 78.57142857142858, "sensitivity_ms_per_mmHg": 0.5, "required_resolution_for_1mmHg_ms": 0.5, "required_resolution_for_5mmHg_ms": 2.5, "required_resolution_for_10mmHg_ms": 5.0, "esp32_max_csi_rate_hz": 1000, "esp32_max_temporal_resolution_ms": 1.0, "esp32_typical_csi_rate_hz": 100, "esp32_typical_temporal_resolution_ms": 10.0 }, "spatial_resolution": { "carotid_femoral_distance_m": 0.55, "fresnel_envelope_5m_link_m": 0.39515292398428903, "fresnel_envelope_2m_link_m": 0.2499166527731462, "sites_resolvable_5m_link": false, "sites_resolvable_2m_link": true, "comment": "Single-link CSI cannot spatially separate two body sites. PTT requires multi-link multistatic with severely ill-posed inverse problem." }, "snr": { "breath_phase_deg": 46.08, "pulse_phase_deg": 1.728, "motion_phase_deg": 11.52, "breath_vs_pulse_amp_ratio": 26.666666666666664, "hr_band_snr_db": 20.0, "bp_contour_required_snr_db": 25.0, "bp_contour_feasibility": "INFEASIBLE" }, "vs_baseline": { "arm_cuff_accuracy_mmHg": 2.0, "published_csi_bp_mae_mmHg": 10.0, "ratio_worse": 5.0 } }