# ESPectre (Francesco Pace) — Technique Reference Source: Pace's *Part 2* (Dec 2025) + [francescopace/espectre](https://github.com/francescopace/espectre) (GPLv3). Living checklist of techniques + RuView adoption status; update when items move. ## 1. Gain Lock (AGC + FFT scale) The ESP32 PHY applies automatic gain control per packet. For normal WiFi reception that keeps decoding optimal; for CSI sensing it manifests as a 20-30 % slow drift in amplitude even in an empty room, masking real body modulation. Two undocumented PHY routines freeze the gain: ```c extern void phy_fft_scale_force(bool force_en, int8_t force_value); extern void phy_force_rx_gain(int force_en, int force_value); ``` Recipe: 1. After WiFi association, collect AGC and FFT gain values from each CSI packet. 2. At packet 300 (~3 s at 100 pps), take the **median** of each (more robust than mean against outliers). 3. Call the two PHY routines with the medians to lock the radio. 4. Safety branch: if median AGC < 30, skip the lock — forcing low gain freezes the RX path. Sensor must be moved further from AP. Supported targets: ESP32-S3, ESP32-C3, ESP32-C5, ESP32-C6. Older parts have no access to these PHY hooks. **RuView status — DONE.** ADR-100 (commit `8aef8206`). Implemented in `firmware/esp32-csi-node/main/csi_collector.c` as `rv_gain_lock_process`. Boot log on both sensors: `gain-lock APPLIED: AGC=42/44, FFT=-31/-42 (median of 300 packets)`. Empty-room CV dropped from ~10 % (full broadband) to 3-4 % after NBVI also kicked in. ## 2. NBVI — Normalized Baseline Variability Index Per-subcarrier score that picks the K most useful subcarriers automatically. ``` NBVI(k) = α · (σ_k / μ_k²) + (1 - α) · (σ_k / μ_k), α = 0.5 ``` * `σ_k / μ_k²` penalises weak subcarriers (low μ → high score → bad). * `σ_k / μ_k` is the standard coefficient of variation; rewards stability. * α = 0.5 balances; pure σ/μ² picks stable-but-quiet bins, pure σ/μ picks loud-but-noisy bins. * Amplitude-only (no phase) — phase has Temporal Phase Rotation artefacts that need extra calibration; amplitude is calibration- free. Four-step pipeline at boot: | Step | What | Detail | |---|---|---| | 1 | **Find quiet moments** | Slide a window across the calibration buffer, pick the windows with the lowest aggregate variance via percentile detection. Tolerates someone walking through during boot. | | 2 | **Dead-zone gate** | Drop any subcarrier with mean amplitude below the 25th percentile across all subcarriers. Guard tones + null bins are excluded so they don't "win" σ/μ² → ∞. | | 3 | **Rank + validate** | Sort by NBVI ascending. Run the motion detector on each candidate config, measure false-positive rate, take the config with the lowest FP. | | 4 | **Pick winners** | Top-K by lowest NBVI (typically K = 12 for HT20). | Memory: O(N) running with on-the-fly mean/variance, ≈ 256 B for 64 subcarriers. Time: O(N · L) per recompute, ms on a $10 device. **RuView status — DONE (all 4 NBVI steps).** Server-side: ADR-102 (`2f12a223`, `f4119924`) covers Steps 1+2+4; ADR-104 D4 (`6212b17e`) closes Step 3 (K ∈ {6,8,10,12,16,20} sweep, smallest-FP wins). FW- side boot freeze remains intentionally absent — server-side rolling refresh adapts to slow channel drift (ADR-102 D6). Empirically on the operator's deployment NBVI alone gave a 1.5-2× CV reduction: | | Full 56 subc | NBVI top-12 | |---|---|---| | node 1 idle CV | 5.0 % | 3.1 % | | node 2 idle CV | 7.0 % | 3.9 % | ## 3. Baseline-variance threshold normalization Pace's third problem was that `threshold = 1.0` meant different things on different devices. Fix: ```python if baseline_variance > 0.25: scale = 0.25 / baseline_variance else: scale = 1.0 ``` Reference 0.25 is what a quiet room typically measures during NBVI calibration. Apply the scale to the live motion score, so the user- facing threshold (`= 1.0`) is universal across rooms. **RuView status — DONE.** ADR-103 D3 (commit `2f4b2d53`). `amp_node_level` and `amp_classify_from_latest` divide live CV by `baseline_cv` loaded from `data/baseline.json` and gate at universal `3×` (moving) / `6×` (active). Falls back to absolute gates `0.10 / 0.22` when no calibration loaded — backwards compatible. ## 4. Two-phase boot calibration ``` PHASE 1: GAIN LOCK (3 s, 300 packets) Collect AGC/FFT → median → lock. PHASE 2: NBVI CALIBRATION (7 s, 700 packets) With gain locked, rank subcarriers → pick top-K. Total ≈ 10 s. Room must be mostly quiet during this window. ``` **RuView status — SPLIT.** Phase 1 is in FW (ADR-100). Phase 2 lives in the server as a rolling refresh, not a boot-time fix-point. See NBVI section above for the implications. ## 5. Persisted baseline / device threshold After NBVI calibration, ESPectre writes the AGC/FFT lock values, the chosen subcarrier set, the baseline variance, and the threshold into NVS so reboots don't need re-calibration. **RuView status — DONE.** Two-layer persistence: * **Server side (ADR-103, commits `f4119924`, `2f4b2d53`)**: `data/baseline.json` keeps per-node full-broadband mean/p95/CV + per-subcarrier means, loaded on server boot via `load_baseline_file`. * **FW side (ADR-108, commit `3779bb76`)**: gain-lock AGC + FFT saved to NVS namespace `csi_cfg` keys `gl_agc`/`gl_fft` after the first calibration; subsequent boots restore instantly (skip the 300-packet sampler). NBVI selection is **intentionally** server- side rolling, not persisted — design choice, not a gap. ## 6. Interactive Web Serial game (`espectre.dev/game`) Browser ↔ ESP32 over USB Web Serial API. Shows live motion as a bar, lets user tune `threshold` while playing a reaction game. Settings persist via NVS. **RuView status — NOT DONE.** Closest analogue is our `raw.html` calibration console (per-node bars + RSSI trace), but it's read-only. ## 7. Native Home Assistant integration via ESPHome Sensor exposes occupancy/motion entities directly to HA. **RuView status — NOT DONE.** No HA integration path. Could be added via MQTT or a custom ESPHome component. ## 8. Test suite Pace ships 500+ unit tests, 90 % coverage, validated against a fixed 2000-packet capture (1000 idle + 1000 motion). CI runs PlatformIO, pytest, ESPHome build, Codecov on every push. **RuView status — PARTIAL.** Agent added 2 regression tests for the binary CSI frame parser (`csi.rs:751`); no regression set captured for the amplitude classifier or NBVI. ## Comparison summary (what RuView has, doesn't have, has differently) | Item | Pace / ESPectre | RuView | |---|---|---| | Gain lock | FW, 300 pkt median, AGC+FFT, AGC<30 skip | ✅ ADR-100 | | NBVI formula α=0.5, top-12, dead-zone gate | ✅ | ✅ ADR-102 | | Quiet-window finder (Step 1) | ✅ | ✅ ADR-102 v2 | | FP-rate validation (Step 3) | ✅ | ❌ raw ranking | | Boot-time NBVI freeze | FW, ~7 s post-lock | ❌ server-side rolling | | Baseline variance normalization (universal threshold) | ✅ | ✅ ADR-103 D3 | | Persisted baseline to disk | NVS | ✅ ADR-103 D1 (`data/baseline.json`) | | NVS persistence of FW calibration | ✅ | ❌ fresh each FW boot | | Calibration UI | Web Serial game | ❌ read-only `raw.html` | | HA / ESPHome integration | ✅ | ❌ none | | Test suite | 500+ tests, 90 % cov | ❌ 2 parser tests | | Phase / amplitude | amplitude only | ✅ same | ## Open items (full gap-by-section: [`espectre-gap-analysis.md`](espectre-gap-analysis.md)) 1. **REST `POST /api/v1/baseline/calibrate`** — drives the recording script from a button in `raw.html` instead of CLI. ~30 min. 2. **FP-rate validation of NBVI pick** — defense against the top-12 accidentally overlapping a noise source. ~1 h. 3. **Per-subcarrier baseline comparison (ADR-104 draft)** — uses the already-saved `per_subcarrier_mean` in `baseline.json` for L2 distance instead of broadband mean ratio. Better off-axis presence sensing. ~1 h. 4. **Auto-recalibrate on long quiet periods** — if classifier sees `absent` with low variance for 30 min, refresh baseline in background. Eliminates manual script step entirely. ~1 h. 5. **FW-side NBVI boot-freeze + NVS persistence** — full reproducibility, sub-second post-boot ready. Trade-off: doesn't adapt to room changes. ~2 h. 6. **HA / ESPHome integration** — sensor as HA entity. ~1 day. 7. **Test suite vs fixed 2 000-packet replay** — regression protection for the classifier + NBVI. ~1 day. 8. **Web Serial calibration game** — nice-to-have. ~1 day.