Commit Graph

3 Commits

Author SHA1 Message Date
ruv 425f0e6aac fix(firmware): defensive node_id capture prevents runtime clobber (#390)
Users on multi-node ESP32 deployments have been reporting for months
that their provisioned `node_id` reverts to the Kconfig default of `1`
in UDP frames and the `csi_collector` init log, despite boot showing:

    nvs_config: NVS override: node_id=4
    main: ESP32-S3 CSI Node (ADR-018) - Node ID: 4
    csi_collector: CSI collection initialized (node_id=1, channel=11)

See #232, #375, #385, #386, #390. The root memory-corruption path for
the `g_nvs_config.node_id` byte has not been definitively isolated
(does not reproduce on my attached ESP32-S3 running current source
and the v0.6.0 release binary), but the UDP frame header can be made
tamper-proof regardless:

1. `csi_collector_init()` now captures `g_nvs_config.node_id` into a
   module-local `static uint8_t s_node_id` at init time.
2. `csi_serialize_frame()` reads `buf[4]` from `s_node_id`, not from
   the global - so any later corruption of `g_nvs_config` cannot
   affect outgoing CSI frames.
3. All other consumers (`edge_processing.c` x3, `wasm_runtime.c`,
   `display_ui.c`, `main.c swarm_bridge_init`) now go through a new
   `csi_collector_get_node_id()` accessor instead of reading the
   global directly.
4. A canary at end-of-init logs `WARN` if `g_nvs_config.node_id`
   already diverges from the captured value - this will pinpoint
   the corruption path if it happens on a user's device.

Hardware validation on attached ESP32-S3 (COM8):
  - NVS loads node_id=2
  - Boot log: `main: ... Node ID: 2`
  - NEW log: `csi_collector: Captured node_id=2 at init (defensive
    copy for #232/#375/#385/#390)`
  - Init log: `csi_collector: CSI collection initialized (node_id=2)`
  - UDP frame byte[4] = 2 (verified via socket sniffer, 15/15 packets)

This is defense in depth - it shields the UDP frame from whatever
upstream bug is clobbering the struct. When a user hits the original
bug, the canary WARN will help isolate the root cause.

Refs #232 #375 #385 #386 #390

Co-Authored-By: claude-flow <ruv@ruv.net>
2026-04-15 13:47:34 -04:00
ruv 8a84748a83 fix(firmware): use NVS node_id instead of Kconfig constant (#279)
CONFIG_CSI_NODE_ID (compile-time, always 1) was hardcoded in 6
places: CSI frame serialization, compressed frames, vitals packets,
WASM output packets, and display UI. NVS provisioning wrote the
correct node_id but it was never used at runtime.

Fixed all occurrences to use g_nvs_config.node_id:
- csi_collector.c: frame header + log message
- edge_processing.c: compressed frame + vitals packet
- wasm_runtime.c: WASM output packet
- display_ui.c: system info display

This means --node-id 0/1/2 provisioning now actually works for
multi-node mesh deployments.

Closes #279

Co-Authored-By: claude-flow <ruv@ruv.net>
2026-03-16 15:12:45 -04:00
ruv 4b1005524e feat: complete vendor repos, add edge intelligence and WASM modules
- Add 154 missing vendor files (gitignore was filtering them)
  - vendor/midstream: 564 files (was 561)
  - vendor/sublinear-time-solver: 1190 files (was 1039)
- Add ESP32 edge processing (ADR-039): presence, vitals, fall detection
- Add WASM programmable sensing (ADR-040/041) with wasm3 runtime
- Add firmware CI workflow (.github/workflows/firmware-ci.yml)
- Add wifi-densepose-wasm-edge crate for edge WASM modules
- Update sensing server, provision.py, UI components

Co-Authored-By: claude-flow <ruv@ruv.net>
2026-03-02 23:53:25 -05:00