Commit Graph

2 Commits

Author SHA1 Message Date
rUv df617145d6
feat(ADR-262 P3): live /api/field + /ws/field — RuView sensing speaks RuField (fail-closed egress) (#1071)
* feat(ADR-262 P3): live RuField surface — RuView sensing speaks RuField on /api/field + /ws/field

Wire the P1 `wifi-densepose-rufield` bridge into the live
`wifi-densepose-sensing-server` so the governed sensing cycle emits real
signed RuField `FieldEvent`s on two additive endpoints.

- Cargo: add the `wifi-densepose-rufield` path dep (the single coupling
  point, ADR-262 §5.4 — no new RuView-internal coupling).
- New `src/rufield_surface.rs` (kept out of the 8k-line main.rs):
  `FieldSurface` holds a dedicated ed25519 `Signer` + a bounded ring of
  recent events + the `/ws/field` broadcast topic; `GET /api/field` and
  `GET /ws/field` handlers; a standalone `router()` for isolated testing.
- Signer (defers the P2 key decision, ADR-262 §8 Q1): a STANDALONE
  dev/sensing key from `WDP_RUFIELD_SIGNING_SEED`, else a deterministic
  dev default with a logged WARN. Reusing the `cog-ha-matter` Ed25519
  key is the deferred P2 call — P3 does not pre-empt it.
- Tap: at the ESP32 governed-trust cycle (`main.rs` ~5886 observe_cycle
  / ~5938 SensingUpdate build), `emit_rufield_event` joins the cycle's
  features/classification/signal_field with the engine's
  effective_class/demoted trust state into a `SensingSnapshot` and
  surfaces it via the bridge. Existing endpoints (`/ws/sensing` etc.)
  are unchanged — purely additive.
- Privacy egress: `network_egress_allowed` is fail-closed for an
  unattended live surface — only P1/P2 leave the box; P0 raw and
  P3/P4/P5 (identity/biometric/aggregate) are held edge-local. A
  `Derived` cycle maps to P4/P5 and never surfaces.
- No-phantom: `emit` drops no-presence cycles (no fabricated events).

Gates (tests/rufield_surface_test.rs, tower::oneshot, 4/0): well-formed
signed event (WifiCsi, P2 not P1, is_fusable, real timestamp); empty
cycle → no phantom; Derived trust never surfaces; mixed stream surfaces
only egress-safe events.

Honesty (ADR-262 §0/§6): real plumbing on a live endpoint, NOT accuracy.
Single-link CSI with its existing caveats (no validated room-coordinate
accuracy); dedicated dev signing key pending the P2 ownership decision;
no accuracy claim.

Co-Authored-By: claude-flow <ruv@ruv.net>

* docs(ADR-262 P3): mark P1+P3 implemented; document /api/field + /ws/field; CHANGELOG

- ADR-262 Status → "P1 + P3 implemented"; add a P3 implementation-status
  block (tap site, endpoints, dedicated dev signer deferring the §8 Q1
  key decision, fail-closed egress, gates). Keep the honesty framing:
  real plumbing on a live endpoint, not accuracy.
- CHANGELOG [Unreleased]: add the ADR-262 P3 entry.
- user-guide: add `/api/field` to the REST table + a "RuField surface
  (ADR-262 P3)" section covering `/api/field` + `/ws/field`, the
  fail-closed P1/P2-only egress, the WDP_RUFIELD_SIGNING_SEED dev key,
  and the no-accuracy honesty note.

Co-Authored-By: claude-flow <ruv@ruv.net>

* ci: checkout submodules everywhere + Dockerfile copies vendor/rufield

Making wifi-densepose-rufield (ADR-262 bridge) a v2 workspace member means
EVERY cargo-on-workspace context must have the vendor/rufield submodule
present (cargo loads all member manifests). P1 only fixed the rust-tests
job; this adds `submodules: recursive` to all workflow checkouts that run
cargo (mqtt-integration was failing on the missing submodule manifest), and
makes Dockerfile.rust COPY vendor/rufield/ to /vendor/rufield (matches the
bridge's ../../../vendor/rufield path-dep under the collapsed Docker layout).
update-submodules.yml left alone (it manages submodules itself).

Co-Authored-By: claude-flow <ruv@ruv.net>

---------

Co-authored-by: ruv <ruvnet@gmail.com>
2026-06-14 13:55:41 -04:00
rUv f250149e94
feat(ADR-262 P1): wifi-densepose-rufield bridge — RuView sensing → signed RuField FieldEvents (fail-closed privacy map) (#1070)
* feat(rufield): ADR-262 P1 — wifi-densepose-rufield anti-corruption bridge

New v2 workspace member that converts RuView WiFi-CSI sensing output into
signed RuField FieldEvents. Path-deps the vendor/rufield submodule crates
(rufield-core/-provenance/-privacy/-fusion); single coupling point between
RuView and the standalone RuField MFS spec (ADR-262 §5.4).

- SensingSnapshot: owned primitives mirroring SensingUpdate + TrustedOutput
  (no dependency on wifi-densepose-sensing-server).
- snapshot_to_field_event(): builds a WifiCsi FieldTensor + Observation,
  derives a real position from the signal-field peak (never fabricated),
  real sha256 provenance + ed25519 signature (synthetic=false).
- map_privacy() (§3.3 crux): maps by information content, NEVER byte value —
  Derived (byte 1) → P4/P5, never P1; fail-closed demotion floor to P2.

P1 gates (tests/p1_gates.rs): round-trip serde, is_fusable verified receipt,
RuFieldFusion::ingest accept + infer runs, privacy-safety (Derived never P1),
full §3.3 table, fail-closed demotion, determinism, no-fabricated-position.
15 tests pass (5 unit + 9 integration + 1 doc), 0 failed.

Honesty: P1 plumbing (tested conversion + safe privacy mapping), NOT wired
into the live server (P3) and NOT an accuracy claim.

Co-Authored-By: claude-flow <ruv@ruv.net>

* docs(adr-262): mark P1 implemented + CI submodules:recursive + CHANGELOG/CLAUDE

- ADR-262 Status → "Proposed — P1 implemented"; add §0.1 Implementation
  status (the bridge crate + the five P1 gates that pass; defers the
  provenance-carrier reuse, P3 live wiring, and P4 multi-modality).
- ci.yml: add `submodules: recursive` to the rust-tests checkout so the new
  crate's `vendor/rufield` path-deps resolve in CI (they fail otherwise even
  though the workspace build passes locally with the submodule present).
- CHANGELOG [Unreleased]: P1 bridge entry (kept alongside the upstream
  ADR-262 research entry).
- CLAUDE.md: crate table row for `wifi-densepose-rufield`.

Co-Authored-By: claude-flow <ruv@ruv.net>
2026-06-14 12:46:58 -04:00