docs(adr): ADR-091 stand-off radar tier research [proposed]
Research-only ADR exploring stand-off radar tiers above 60 GHz: 77-81 GHz high-power and 100-200 GHz coherent sub-THz. Triggered by Ghost Murmur spec (doc 16) §6.3 explicitly deferring military-class radar as out of scope. Decision matrix: - Skip permanently: 77 GHz beyond §95.M ceiling, 220 GHz coherent stand-off hardware, 380+ GHz imaging. - Research only (simulator-class artifact, mirroring nvsim ADR-089/090): 77 GHz at §95.M ceiling, 100 GHz coherent mesh, 140 GHz coherent stand-off. - Build now: nothing. If RuView ever builds anything in this space, it builds a sub-THz forward simulator (subthz-radar-sim) following the nvsim pattern: deterministic, host-side, witness-verified, no firmware. Conditional triggers gate any build: sub-\$1k COTS sub-THz transceiver AND clear medical/non-export- controlled application AND RuView core RFC sign-off. Grounded in primary sources: Massagram 2013 (24 GHz HR @ 21 m), imec 2019 (140 GHz CMOS demonstrator), ITU-R P.676 (atmospheric attenuation), 47 CFR Part 95 Subpart M (76-81 GHz EIRP caps), BIS ECCN 6A008 (radar export control). Co-Authored-By: claude-flow <ruv@ruv.net>
This commit is contained in:
parent
b2dd5851c0
commit
508e2c65d4
|
|
@ -0,0 +1,770 @@
|
|||
# ADR-091: Stand-off Radar Tier Research — 77 GHz High-Power and 100–200 GHz Coherent Sub-THz
|
||||
|
||||
| Field | Value |
|
||||
|----------------|-----------------------------------------------------------------------------------------|
|
||||
| **Status** | Proposed — Research only. No production hardware integration. Decision deferred pending sub-$1k COTS sub-THz transceiver availability and clear non-export-controlled use case. |
|
||||
| **Date** | 2026-04-26 |
|
||||
| **Authors** | ruv |
|
||||
| **Refines** | ADR-021 (60 GHz / mmWave vital-signs pipeline) |
|
||||
| **Companion** | `docs/research/quantum-sensing/16-ghost-murmur-ruview-spec.md` §6.3, ADR-029 (RuvSense multistatic), ADR-089 (nvsim simulator), ADR-090 (Lindblad extension) |
|
||||
|
||||
## 1. Context
|
||||
|
||||
### 1.1 Why this question now
|
||||
|
||||
On Good Friday 3 April 2026 the press reported a CIA system called "Ghost Murmur"
|
||||
— a Lockheed Skunk Works NV-diamond + AI sensor reportedly used in the recovery
|
||||
of an F-15E pilot in southern Iran. President Trump publicly suggested detection
|
||||
ranges in the "tens of miles" against a single human heartbeat. RuView shipped
|
||||
a research spec (`16-ghost-murmur-ruview-spec.md`) which (a) reality-checked the
|
||||
press claims against published physics, (b) mapped the *honestly-scoped* version
|
||||
onto the existing RuView three-tier mesh, and (c) explicitly deferred one
|
||||
modality — high-power and sub-THz coherent radar — as out of scope. From §6.3
|
||||
of that spec:
|
||||
|
||||
> 77 GHz automotive radars at higher power and 100–200 GHz coherent sub-THz
|
||||
> radars **can** resolve cardiac micro-Doppler at 50–500 m in clear LOS. These
|
||||
> are not COTS at the $15 price point and are not in the RuView stack today.
|
||||
> They are also subject to ITAR / export-control review and **explicitly out of
|
||||
> scope** for this open-source project.
|
||||
|
||||
That sentence is the trigger for this ADR. We need a written, citable record of
|
||||
*why* the decision is "out of scope today", what would change the decision,
|
||||
and — crucially — what shape any future research entry into this band would
|
||||
take, given that even the research itself touches dual-use territory.
|
||||
|
||||
### 1.2 What gap a higher-frequency / higher-power tier would close
|
||||
|
||||
RuView's existing modality coverage (per the CLAUDE.md crate table):
|
||||
|
||||
| Modality | Crate / ADR | Honest LOS range for HR | Through-wall HR |
|
||||
|---|---|---|---|
|
||||
| WiFi CSI 2.4/5/6 GHz | `wifi-densepose-signal`, ADR-014, ADR-029 | 1–3 m (presence to 30 m) | 1 wall, weak |
|
||||
| 60 GHz FMCW (MR60BHA2) | `wifi-densepose-vitals`, ADR-021 | 1–10 m | drywall only |
|
||||
| NV-diamond magnetometer | `nvsim` (simulator), ADR-089/090 | <1 m (gradiometric, shielded) | n/a |
|
||||
|
||||
The ceiling of this stack on cardiac micro-Doppler in clear line-of-sight is
|
||||
**~10 m** (60 GHz tier, ADR-021 / spec §6.1). A higher-frequency / higher-power
|
||||
tier would, in principle, close the 10–500 m gap that the published radar
|
||||
literature has already explored. The two candidate bands:
|
||||
|
||||
1. **77–81 GHz at higher than typical commercial EIRP** — the same band as
|
||||
automotive radar, where the FCC ceiling is 50 dBm average / 55 dBm peak EIRP
|
||||
under 47 CFR §95.M, and where published academic work has measured HR at
|
||||
ranges beyond the typical 1–3 m used by COTS automotive sensors.
|
||||
2. **100–200 GHz coherent sub-THz radar** — where λ ≈ 1.5–3 mm gives
|
||||
sub-millimetre chest-wall displacement resolution and where atmospheric
|
||||
transmission windows at 94 GHz, 140 GHz, and 220 GHz make stand-off sensing
|
||||
physically possible (with caveats on humidity, antenna gain, and integration
|
||||
time).
|
||||
|
||||
This ADR examines both bands — the SOTA, the COTS reality, the regulatory
|
||||
envelope, the physics ceiling, the export-control posture, and the open-source
|
||||
ethics — and lands at a build / research / skip recommendation per row.
|
||||
|
||||
## 2. SOTA: 77–81 GHz automotive radar at higher power
|
||||
|
||||
### 2.1 Current COTS chips at the $20–$200 price point
|
||||
|
||||
The 76–81 GHz band is now densely populated with single-chip CMOS / SiGe
|
||||
transceivers. Representative parts:
|
||||
|
||||
| Chip | Vendor | Tx / Rx | IF BW | Notes |
|
||||
|---|---|---|---|---|
|
||||
| AWR1843 | Texas Instruments | 3 Tx / 4 Rx | up to ~10 MHz IF | Single-chip 76–81 GHz with on-die DSP, MCU, radar accelerator. Long-range automotive ACC, AEB. ([TI AWR1843](https://www.ti.com/product/AWR1843)) |
|
||||
| AWR2243 | Texas Instruments | 3 Tx / 4 Rx | up to ~20 MHz IF | Cascadable for higher angular resolution (up to 12 Tx / 16 Rx with multi-chip cascade). ([TI AWR2243](https://www.ti.com/product/AWR2243)) |
|
||||
| BGT60 family | Infineon | 1–3 Tx / 1–4 Rx | Several MHz IF | 60 GHz primarily; BGT24 family at 24 GHz. Smaller, lower power, gesture / presence focus. |
|
||||
| TEF82xx | NXP | up to 4 Tx / 4 Rx | several MHz IF | Automotive-grade 76–81 GHz. |
|
||||
|
||||
COTS evaluation boards (TI AWR1843BOOST, AWR2243 cascade kits) sit in the
|
||||
$300–$3,000 range; single-board production costs trend toward $20–$100 at
|
||||
volume. None of these chips is, by itself, export-controlled at typical
|
||||
configurations — the band is allocated for civilian automotive use under FCC
|
||||
Part 95 Subpart M and ETSI EN 301 091 in Europe.
|
||||
|
||||
**EIRP envelope**: 47 CFR §95.M (and the historical §15.253 it replaced) caps
|
||||
the 76–81 GHz band at **50 dBm average / 55 dBm peak EIRP** measured in 1 MHz
|
||||
RBW ([Federal Register notice 2017](https://www.federalregister.gov/documents/2017/09/20/2017-18463/permitting-radar-services-in-the-76-81-ghz-band),
|
||||
[eCFR 47 CFR Part 95 Subpart M](https://www.ecfr.gov/current/title-47/chapter-I/subchapter-D/part-95/subpart-M)).
|
||||
That is roughly 100 W EIRP average, 316 W peak. COTS automotive radars
|
||||
typically operate well below this — single-digit dBm transmit power is
|
||||
multiplied by ~25–30 dBi antenna gain to land at 33–40 dBm EIRP.
|
||||
|
||||
### 2.2 What "higher power" actually means in regulatory terms
|
||||
|
||||
Three regulatory paths exist for an open-source project that wants to push
|
||||
beyond typical commercial deployment power:
|
||||
|
||||
1. **Stay inside FCC Part 95 §95.M caps (50 dBm avg / 55 dBm peak EIRP)** —
|
||||
licence-by-rule, no application, no individual approval. The headroom from
|
||||
typical automotive EIRP (~33–40 dBm) to the cap (50 dBm avg) is real:
|
||||
~10 dB of additional EIRP is available *without changing licence class*,
|
||||
purely by using a higher-gain dish or higher Tx power within the existing
|
||||
chip. This is the upper bound of "stand-off radar that is still part-95
|
||||
legal".
|
||||
2. **FCC Part 5 experimental licence** — needed for transmit power, antenna
|
||||
gain, or duty-cycle that exceeds §95.M. Application-based, time-bounded,
|
||||
non-renewable beyond limits. Typical academic radar ranges (e.g. the
|
||||
long-range cardiac measurements in §2.3 below) operate under this regime.
|
||||
3. **No US authorisation at all** — only legal as receive-only, or as a
|
||||
simulator. Any unlicensed transmission above §95.M at 76–81 GHz is a
|
||||
prohibited emission under 47 CFR §15.5 / §95.335.
|
||||
|
||||
For an *open-source mesh node* shipping to anonymous users worldwide, only
|
||||
path (1) is defensible. Anything that requires an individual experimental
|
||||
licence cannot be "ship a binary and let people flash it".
|
||||
|
||||
### 2.3 Published cardiac micro-Doppler at 77 GHz beyond 5 m
|
||||
|
||||
The 77 GHz cardiac literature is dominated by short-range work (0.3–2 m), e.g.:
|
||||
|
||||
- Chen et al. (2024). "Contactless and short-range vital signs detection with
|
||||
doppler radar millimetre-wave (76–81 GHz) sensing firmware." *Healthcare
|
||||
Technology Letters*. ([PMC11665778](https://pmc.ncbi.nlm.nih.gov/articles/PMC11665778/),
|
||||
[Wiley HTL 2024](https://ietresearch.onlinelibrary.wiley.com/doi/full/10.1049/htl2.12075))
|
||||
— TI IWR1443BOOST at 0.30–1.20 m, suggested 0.6 m.
|
||||
- Wang et al. (2020). "Remote Monitoring of Human Vital Signs Based on 77-GHz
|
||||
mm-Wave FMCW Radar." *Sensors* 20, 2999.
|
||||
([PMC7285495](https://pmc.ncbi.nlm.nih.gov/articles/PMC7285495/),
|
||||
[MDPI Sensors 2020](https://www.mdpi.com/1424-8220/20/10/2999)) — typically
|
||||
short-range bench measurements.
|
||||
- Liu et al. (2022). "Real-Time Heart Rate Detection Method Based on 77 GHz
|
||||
FMCW Radar." *Micromachines* 13, 1960.
|
||||
([PMC9693980](https://pmc.ncbi.nlm.nih.gov/articles/PMC9693980/),
|
||||
[MDPI](https://www.mdpi.com/2072-666X/13/11/1960)) — 2.925% mean HR error,
|
||||
short-range.
|
||||
- Iyer et al. (2022). "mm-Wave Radar-Based Vital Signs Monitoring and
|
||||
Arrhythmia Detection Using Machine Learning." *Sensors*.
|
||||
([PMC9104941](https://pmc.ncbi.nlm.nih.gov/articles/PMC9104941/))
|
||||
|
||||
The most cited *long-range* radar cardiac measurement is at 24 GHz, not 77 GHz:
|
||||
|
||||
- **Massagram, W., Lubecke, V. M., Høst-Madsen, A., Boric-Lubecke, O. (2013).
|
||||
"Parametric Study of Antennas for Long Range Doppler Radar Heart Rate
|
||||
Detection."** *IEEE EMBC* / republished in *PMC*.
|
||||
([PMC4900816](https://pmc.ncbi.nlm.nih.gov/articles/PMC4900816/),
|
||||
[PubMed 23366747](https://pubmed.ncbi.nlm.nih.gov/23366747/)) —
|
||||
measured human HR at distances of **1, 3, 6, 9, 12, 15, 18, 21 m** and
|
||||
respiration to **69 m** with a PA24-16 antenna at **24 GHz CW Doppler**.
|
||||
This is the ceiling reference for "what's achievable with serious antenna
|
||||
gain in clear LOS, low band, with subject cued and stationary".
|
||||
|
||||
We could not find an equivalent peer-reviewed cardiac measurement at 77 GHz
|
||||
*beyond ~5 m* with a verifiable antenna gain × power × integration-time
|
||||
budget. The work that exists at 77 GHz is overwhelmingly bench-scale (≤ 2 m).
|
||||
This is itself informative: it suggests that *the open published frontier at
|
||||
77 GHz beyond 5 m is sparse*, not because it's impossible, but because the
|
||||
research community working at automotive bands has been focused on automotive
|
||||
problems (collision avoidance, in-cabin occupancy) where 5 m suffices, and
|
||||
because higher-range cardiac work has historically used 24 GHz where the
|
||||
antenna size for a given gain is more practical.
|
||||
|
||||
### 2.4 Detection range as a function of antenna gain × power × integration time
|
||||
|
||||
The radar equation for chest-wall displacement detection scales roughly as:
|
||||
|
||||
```
|
||||
SNR ∝ (P_t · G_t · G_r · σ_chest) / (R^4 · k T B · NF) · √(t_int / T_coh)
|
||||
```
|
||||
|
||||
where σ_chest ≈ 10⁻³–10⁻² m² for the cardiac scatterer at 77 GHz, NF ≈ 10–15 dB
|
||||
on COTS chips, and integration time t_int is bounded by T_coh ≈ 0.5–1 s
|
||||
(physiological coherence — the heart period itself).
|
||||
|
||||
Doubling range requires 12 dB of system gain (4-th power dependence on R,
|
||||
two-way). At the part-95 §95.M ceiling (50 dBm avg EIRP) and a generous 30 dB
|
||||
antenna gain (a ~30 cm dish at 77 GHz), the addressable HR detection range in
|
||||
clear LOS is roughly **15–30 m for a stationary cued subject**, dropping to
|
||||
3–10 m for an uncued subject in light clutter. Pushing to 100 m+ in an open
|
||||
field would require either (a) a much larger antenna (60+ cm dish), (b)
|
||||
out-of-band EIRP beyond §95.M (experimental licence territory), or (c) much
|
||||
longer integration (incompatible with cardiac coherence times).
|
||||
|
||||
The 2013 Massagram paper achieves 21 m at 24 GHz with a high-gain antenna
|
||||
under tightly controlled conditions. Pushing the same setup to 77 GHz with
|
||||
the same antenna *aperture* would actually help (smaller beamwidth, same
|
||||
free-space path loss), but the chest-wall RCS at 77 GHz is comparable, and
|
||||
clutter / multipath are much harsher. We have **no public reference** for a
|
||||
77 GHz cardiac measurement at 21 m that we could find with the same rigour.
|
||||
|
||||
### 2.5 Cost ceiling for an open-source mesh node
|
||||
|
||||
An open-source mesh node spec implies "ships in a kit, does not require
|
||||
individual licensing, fits the existing PoE / mini-PC edge model". That
|
||||
implies:
|
||||
|
||||
- Single-chip transceiver at $20–$100 BOM.
|
||||
- Antenna assembly at $50–$200 (high-gain dish or printed array).
|
||||
- Mini-PC or Pi 5 host at $80.
|
||||
- Total under $500 to be plausible.
|
||||
|
||||
The chip cost is already met by COTS. The antenna and host are met. The
|
||||
bottleneck is *not* hardware cost — it is regulatory exposure, dual-use
|
||||
ethics, and the fact that the addressable range at part-95 ceilings (15–30 m)
|
||||
is *only marginally beyond* what the existing 60 GHz tier already does for
|
||||
$15. The marginal *technical* benefit of jumping to 77 GHz at the part-95
|
||||
ceiling, for a civilian opt-in mesh, does not clear the marginal *governance*
|
||||
cost.
|
||||
|
||||
## 3. SOTA: 100–200 GHz coherent sub-THz radar
|
||||
|
||||
### 3.1 Why sub-THz
|
||||
|
||||
At 140 GHz, λ ≈ 2.14 mm. A coherent radar with this wavelength can resolve
|
||||
chest-wall displacement at the **sub-millimetre** level by direct phase
|
||||
tracking, which makes the cardiac micro-Doppler signal-to-clutter ratio
|
||||
fundamentally better than at 60 or 77 GHz for the same integration time.
|
||||
Atmospheric *windows* at 94 GHz, 140 GHz, and 220 GHz — between the strong
|
||||
oxygen absorption peaks at 60 GHz and 119 GHz and the water vapour peaks at
|
||||
22, 183, and 325 GHz — make stand-off operation physically possible per
|
||||
**ITU-R Recommendation P.676** ([ITU-R P.676-11](https://www.itu.int/dms_pubrec/itu-r/rec/p/R-REC-P.676-11-201609-I!!PDF-E.pdf),
|
||||
[ITU-R P.676-9](https://www.itu.int/dms_pubrec/itu-r/rec/p/R-REC-P.676-9-201202-S!!PDF-E.pdf)).
|
||||
|
||||
### 3.2 Atmospheric attenuation table (clear-air, ITU-R P.676)
|
||||
|
||||
Order-of-magnitude values for one-way attenuation through standard atmosphere
|
||||
at sea level, taken from ITU-R P.676-11 Annex 1 / 2 figures (approximate
|
||||
values; consult the recommendation for precise numbers at any (T, P, ρ)):
|
||||
|
||||
| Frequency | Dry air, dB/km | 7.5 g/m³ humid, dB/km | Notes |
|
||||
|---|---|---|---|
|
||||
| 60 GHz | ~14 | ~14.5 | O₂ absorption peak — terrible for stand-off |
|
||||
| 77 GHz | ~0.4 | ~0.5 | Allocated for automotive radar |
|
||||
| 94 GHz | ~0.4 | ~0.7 | First major window above 60 GHz |
|
||||
| 119 GHz | ~2.5 | ~3 | O₂ subsidiary peak |
|
||||
| 140 GHz | ~0.5 | ~1.5 | Second major window |
|
||||
| 183 GHz | ~30+ | ~100+ | H₂O peak — unusable for outdoor stand-off |
|
||||
| 220 GHz | ~2 | ~5 | Third window |
|
||||
| 325 GHz | ~10+ | ~50+ | H₂O peak |
|
||||
| 380 GHz | ~3 | ~20 | Imaging-band window, very humidity-sensitive |
|
||||
|
||||
For a 100 m one-way clear-LOS link at 140 GHz in 7.5 g/m³ humidity, atmospheric
|
||||
attenuation alone is ~0.15 dB — negligible compared to free-space path loss
|
||||
(~115 dB at 100 m) and target RCS. The atmosphere is *not* the limiting factor
|
||||
for sub-THz cardiac sensing inside ~100 m. **Beyond ~1 km in humid conditions,
|
||||
atmospheric absorption dominates** and the budget breaks down quickly,
|
||||
especially at 220 GHz and above.
|
||||
|
||||
### 3.3 COTS chipsets and academic platforms
|
||||
|
||||
The sub-THz commercial landscape in 2026 is sparse and expensive:
|
||||
|
||||
- **Analog Devices HMC8108** — 76–81 GHz transceiver. Not sub-THz; named here
|
||||
only to anchor "the most COTS-friendly mmWave part Analog Devices ships".
|
||||
- **Virginia Diodes WR-* multipliers and mixers** — the dominant lab-grade
|
||||
source for 140–500 GHz work. Module prices are $5,000–$50,000 each;
|
||||
building a coherent transceiver typically requires $30,000–$150,000 of VDI
|
||||
hardware plus a stable phase reference and an external RF source.
|
||||
- **Wasa Millimeter Wave imagers** — passive imagers around 90 / 220 / 380 GHz.
|
||||
Receive-only.
|
||||
- **imec 140 GHz FMCW transceiver in 28 nm CMOS** — reported at IEEE ISSCC and
|
||||
in *Microwave Journal* (2019), centred at 145 GHz with 13 GHz RF bandwidth
|
||||
giving 11 mm range resolution, on-chip antennas, integrated Tx / Rx in 28 nm
|
||||
bulk CMOS. ([Microwave Journal 2019](https://www.microwavejournal.com/articles/32446-integrated-140-ghz-fmcw-radar-for-vital-sign-monitoring-and-gesture-recognition),
|
||||
[imec magazine May 2019](https://www.imec-int.com/en/imec-magazine/imec-magazine-may-2019/a-compact-140ghz-radar-chip-for-detecting-small-movements-such-as-heartbeats))
|
||||
This is the most COTS-relevant sub-THz cardiac chip published to date,
|
||||
but it is **not** a buyable part — it is a research demo.
|
||||
- **Academic platforms** at Tampere University, FAU Erlangen-Nürnberg, Bell Labs
|
||||
/ Nokia, MIT Lincoln Lab, and the various US NSF / DARPA-funded sub-THz
|
||||
programmes have produced sub-THz radars in the 100–300 GHz band. None of
|
||||
these is a ship-it part.
|
||||
|
||||
### 3.4 Coherent vs. incoherent
|
||||
|
||||
A *coherent* sub-THz radar maintains phase reference between Tx and Rx (and
|
||||
ideally across multiple Tx / Rx channels for MIMO or multistatic operation).
|
||||
Coherent processing buys:
|
||||
|
||||
- **Matched-filter SNR scaling**: SNR improves linearly with integration
|
||||
time t (vs. √t for incoherent), bounded by the cardiac coherence
|
||||
time T_coh.
|
||||
- **Phase-based displacement extraction**: chest-wall displacement at the
|
||||
micrometre level becomes directly observable as Δφ = 4π·Δd / λ.
|
||||
- **MIMO / multistatic phase coherence**: multiple Tx / Rx phase-coherent
|
||||
channels enable beamforming gain that scales as N_Tx × N_Rx instead of
|
||||
√(N_Tx × N_Rx).
|
||||
|
||||
It costs:
|
||||
|
||||
- **Sub-picosecond clock distribution** between channels at sub-THz frequencies
|
||||
(a 1 ps clock skew at 140 GHz is 50° of phase error).
|
||||
- **Phase-locked LO distribution** — the LO must be coherent across the
|
||||
array; this is non-trivial at 140 GHz (typical solution: distribute a low
|
||||
GHz reference and multiply locally, with cm-precision cable matching).
|
||||
- **Calibration burden** — phase-coherent arrays need per-channel calibration
|
||||
drift correction.
|
||||
|
||||
For a single-aperture monostatic radar (one Tx, one Rx, one chip), coherence
|
||||
is nearly free (the LO is shared on-die). For a *mesh* of coherent sub-THz
|
||||
nodes, the engineering cost is significant — and would require RuView to
|
||||
develop sub-ns mesh clock-synchronisation it does not have today.
|
||||
|
||||
### 3.5 Published cardiac micro-Doppler at sub-THz
|
||||
|
||||
The published peer-reviewed cardiac literature at 100–300 GHz is sparse but
|
||||
not empty:
|
||||
|
||||
- **Mostafanezhad & Boric-Lubecke (2014).** "Benefits of coherent low-IF for
|
||||
vital signs monitoring." *IEEE Microw. Wireless Compon. Lett.* 24. — anchor
|
||||
for *coherent* CW vital-signs radar; not specifically sub-THz, but
|
||||
establishes the coherent-IF advantage.
|
||||
- **imec (2019) — 140 GHz FMCW transceiver demonstration.** Reported real-time
|
||||
measurement of micro-skin motion reflecting respiration and heartbeat at
|
||||
short range using an integrated 28 nm CMOS transceiver with on-chip antennas.
|
||||
Cited above; engineering demo, not a published systematic range study.
|
||||
([Microwave Journal 2019](https://www.microwavejournal.com/articles/32446-integrated-140-ghz-fmcw-radar-for-vital-sign-monitoring-and-gesture-recognition))
|
||||
- **Yamagishi et al. (2022).** "A new principle of pulse detection based on
|
||||
terahertz wave plethysmography." *Scientific Reports* 12, 2022.
|
||||
([Nature SREP](https://www.nature.com/articles/s41598-022-09801-w)) —
|
||||
THz-band plethysmography demonstrator, contactless pulse detection at very
|
||||
short range using THz transmission/reflection through skin. Not a stand-off
|
||||
radar paper, but the only widely-cited THz-cardiac primary source.
|
||||
- **Zhang et al. (2021).** "Non-Contact Monitoring of Human Vital Signs Using
|
||||
FMCW Millimeter Wave Radar in the 120 GHz Band." *Sensors* 21.
|
||||
([PMC8070581](https://pmc.ncbi.nlm.nih.gov/articles/PMC8070581/)) — 120 GHz
|
||||
band, FMCW, short-range cardiac extraction.
|
||||
|
||||
**Honest assessment**: published primary work on cardiac micro-Doppler at
|
||||
*beyond a few meters* in the 100–300 GHz band is limited. The
|
||||
imec / EU-funded demonstrators have shown that the chip exists; the systematic
|
||||
range studies that exist for 24 GHz (Massagram 2013) and 60–77 GHz
|
||||
(Adib / Wang / Liu) do not yet have published sub-THz analogues. Some of this
|
||||
work may exist in the classified or US-Government / EU defence-funded
|
||||
literature; it is **not** in the open record at the level of detail required
|
||||
for a build decision.
|
||||
|
||||
## 4. Physics ceiling for RuView's heartbeat-mesh use case
|
||||
|
||||
### 4.1 Cardiac signal vs. distance, multi-band comparison
|
||||
|
||||
For a stationary, cued, line-of-sight subject with chest-wall displacement
|
||||
~0.2 mm at the heart fundamental and ~5 mm at the breathing fundamental,
|
||||
order-of-magnitude HR-detection range estimates at three bands (compiled from
|
||||
the radar equation, Massagram 2013, ITU-R P.676, and standard chest-RCS
|
||||
estimates):
|
||||
|
||||
| Band | λ | Required Δφ for HR | Free-space loss @ 30 m | Atm loss @ 30 m | Estimated HR range (cued LOS, COTS Tx + 30 dBi antenna, part-95) |
|
||||
|---|---|---|---|---|---|
|
||||
| 24 GHz CW | 12.5 mm | 0.36° | 89 dB | <0.01 dB | 21 m measured (Massagram 2013) |
|
||||
| 60 GHz FMCW | 5.0 mm | 0.9° | 97 dB | 0.4 dB | 5–10 m (ADR-021 / spec §6.1) |
|
||||
| 77 GHz FMCW | 3.9 mm | 1.2° | 99 dB | 0.01 dB | ~15–30 m (estimated, no rigorous public ref beyond 5 m) |
|
||||
| 140 GHz FMCW | 2.1 mm | 2.2° | 105 dB | 0.04 dB | ~30–100 m (estimated, sparse open lit) |
|
||||
| 220 GHz FMCW | 1.4 mm | 3.3° | 109 dB | 0.15 dB | ~30–100 m (estimated, sparse open lit, humidity-sensitive) |
|
||||
|
||||
The phase-displacement resolution *improves* with frequency (Δφ for the same
|
||||
displacement scales as 1/λ), but the link budget *degrades* (R⁻⁴ in
|
||||
two-way path loss, plus atmospheric absorption, plus higher noise figure on
|
||||
sub-THz LNAs). The two effects partially cancel; the net result is that
|
||||
**every doubling in frequency above 60 GHz buys roughly a factor of 2–4× in
|
||||
plausible HR range when antenna aperture is held constant** — but only if
|
||||
the system noise figure and Tx power can be maintained at levels comparable
|
||||
to the lower-band part. Sub-THz CMOS NF is typically 10 dB worse than 77 GHz
|
||||
CMOS, which eats much of the apparent gain.
|
||||
|
||||
### 4.2 Two-way path loss + atmospheric absorption
|
||||
|
||||
| Range | 77 GHz total loss | 140 GHz total loss | 220 GHz total loss |
|
||||
|---|---|---|---|
|
||||
| 1 m | 70 dB + 0 | 76 dB + 0 | 80 dB + 0 |
|
||||
| 10 m | 90 dB + 0.01 | 96 dB + 0.03 | 100 dB + 0.1 |
|
||||
| 100 m | 110 dB + 0.1 | 116 dB + 0.3 | 120 dB + 1 |
|
||||
| 1 km | 130 dB + 1 | 136 dB + 3 | 140 dB + 10 |
|
||||
| 10 km | 150 dB + 10 | 156 dB + 30 | 160 dB + 100 |
|
||||
| 65 km (40 mi) | 168 dB + 65 | 174 dB + 200+ | 178 dB + impossible |
|
||||
|
||||
**Observations**:
|
||||
|
||||
- At 1 km, 220 GHz loses 9 dB more to atmosphere than 77 GHz; at 10 km it
|
||||
loses 90 dB more. Sub-THz is fundamentally a sub-1-km modality in humid air.
|
||||
- At 65 km (the "40 miles" in the press), atmospheric absorption alone makes
|
||||
220 GHz cardiac detection physically impossible at any plausible Tx power.
|
||||
140 GHz needs 200+ dB of antenna gain on each end to close the link in
|
||||
humid air — far beyond any deployable antenna.
|
||||
- **77 GHz is the only band where 1 km cardiac sensing is physically plausible
|
||||
in the open air.** It is also the band that is closest to civilian COTS.
|
||||
|
||||
### 4.3 Required antenna gain × power × integration time
|
||||
|
||||
Holding integration time at 0.5 s (half a cardiac cycle, the rough coherence
|
||||
limit), and assuming a 10 dB SNR target at 0.2 mm displacement, the required
|
||||
EIRP × antenna-gain product to detect HR at various ranges in clear LOS at
|
||||
77 GHz:
|
||||
|
||||
| Range | Required EIRP × G_r (one-way) | Achievable under FCC §95.M? |
|
||||
|---|---|---|
|
||||
| 1 m | 25 dBm + 20 dBi | Yes (commercial COTS) |
|
||||
| 10 m | 45 dBm + 30 dBi | Yes (high-end COTS, 30 cm dish) |
|
||||
| 30 m | 55 dBm + 35 dBi | Marginal — at the §95.M peak ceiling |
|
||||
| 100 m | 70 dBm + 45 dBi | No — above §95.M, experimental-licence territory |
|
||||
| 500 m | 90 dBm + 55 dBi | No — military / experimental only |
|
||||
| 1 km | 100 dBm + 60 dBi | No — military only |
|
||||
| 10+ km | beyond physical antenna realisability for civilian use | No |
|
||||
|
||||
**Bottom line**: 30 m is the honest ceiling for cardiac sensing inside FCC
|
||||
§95.M power limits with a 30 cm dish at 77 GHz. Anything beyond ~30 m is
|
||||
either experimental-licence territory or military.
|
||||
|
||||
### 4.4 Fold-over with the Ghost Murmur "tens of miles" claim
|
||||
|
||||
The press claim of HR detection at "40 miles" (65 km) corresponds to a one-way
|
||||
path loss at 77 GHz of roughly 168 dB (free space) plus ~65 dB of atmospheric
|
||||
absorption (humid). Closing this link to detect a 0.2 mm chest-wall
|
||||
displacement would require:
|
||||
|
||||
- **Required EIRP**: roughly 200 dBm (10²⁰ W) in the simplest analysis. For
|
||||
context, the entire global average solar flux is ~1.4 kW/m². A 65 km
|
||||
radar would need to deliver more transmit power, focused onto a single
|
||||
human chest, than the sun delivers to that chest by daylight.
|
||||
- **Required antenna**: even with 100 dB of combined two-way antenna gain
|
||||
(a 6 m dish at 77 GHz), the EIRP requirement is unphysical.
|
||||
- **Required atmospheric conditions**: dry, stable, no rain, no fog, no
|
||||
intervening terrain.
|
||||
|
||||
The honest reading: **HR detection at "tens of miles" against a single
|
||||
heartbeat is not consistent with any physically realisable open-air radar
|
||||
system at any band the laws of physics allow**. The claim either refers to
|
||||
*cued* detection (i.e., a survival beacon or IR thermal already pinpointed
|
||||
the target, the radar is just confirming "alive"), or it is press-release
|
||||
hyperbole. RuView is not in a position to either confirm or contest the
|
||||
operational reality; we are in a position to say that the *modality alone* —
|
||||
"detect a heartbeat at 40 miles with a radar" — is not what closed the loop.
|
||||
|
||||
This is consistent with the Ghost Murmur spec's analysis (§4 of doc 16) and
|
||||
with `nvsim`'s magnetic-field falloff calculations (1/r³ — even more brutal
|
||||
than radar's 1/r⁴).
|
||||
|
||||
## 5. Regulatory + ethics
|
||||
|
||||
### 5.1 FCC envelope summary
|
||||
|
||||
| Use | FCC path | Practical for open source? |
|
||||
|---|---|---|
|
||||
| 60 GHz unlicensed (existing tier) | Part 15.255 (57–71 GHz) | Yes — current tier |
|
||||
| 76–81 GHz at COTS automotive EIRP | Part 95 Subpart M (50/55 dBm) | Yes — research-allowed |
|
||||
| 76–81 GHz pushing toward §95.M ceiling | Part 95 Subpart M | Yes — single-installation |
|
||||
| 76–81 GHz beyond §95.M | Part 5 experimental licence | **No** for shipping firmware |
|
||||
| 90–300 GHz coherent radar | Mostly experimental-only | **No** for shipping firmware |
|
||||
| 300+ GHz transmitters | Almost all unallocated for civilian active use | **No** for shipping firmware |
|
||||
|
||||
For an *open-source civilian project*, only the unlicensed and part-95
|
||||
licensed-by-rule categories are defensible. The moment a node would need an
|
||||
individual experimental-licence application to operate legally, it cannot be
|
||||
"flash and ship".
|
||||
|
||||
### 5.2 ITAR / EAR posture
|
||||
|
||||
- **ECCN 6A008** controls radar systems and components under the EAR
|
||||
([BIS Commerce Control List Cat. 6](https://www.bis.doc.gov/index.php/documents/regulations-docs/2340-ccl9-4/file)).
|
||||
The general radar control sub-paragraph 6A008.e covers "radar systems,
|
||||
having any of the following characteristics" — including high power,
|
||||
specific frequency / coherence properties, and certain processing
|
||||
capabilities. The exact thresholds change from revision to revision; the
|
||||
current authoritative source is the [BIS Interactive Commerce Control
|
||||
List](https://www.bis.gov/regulations/ear/interactive-commerce-control-list).
|
||||
- **USML Category XI(c)** (ITAR) covers radar that is specifically designed
|
||||
or modified for military application. Sub-THz coherent radar with the
|
||||
combination of frequency, coherence, and antenna gain that would matter
|
||||
for stand-off cardiac sensing tends to fall in or near this category.
|
||||
- **EAR99 / no-licence-required** thresholds for low-power 60–77 GHz
|
||||
automotive radar are clear. Sub-THz coherent radar above certain
|
||||
thresholds (ECCN 6A008) requires an export licence for many destinations.
|
||||
Some open-source firmware that *implements* such a radar may be subject
|
||||
to "publicly available" exemptions; some may not.
|
||||
- **Open-source publication.** EAR §734.7 / §734.8 ("publicly available
|
||||
information") exempts most code that has been or will be published openly.
|
||||
However, this exemption has limits — particularly for "specially designed"
|
||||
technology supporting controlled commodities, and for encryption / certain
|
||||
munitions categories. The line for radar firmware is not fully clear, and
|
||||
the safe path for an open-source project is: **do not publish firmware
|
||||
whose primary purpose is to push a controlled-radar configuration**.
|
||||
|
||||
The correct posture for RuView is: **assume the worst case**. If RuView
|
||||
*shipped* firmware that drove a 140 GHz coherent sub-THz cardiac mesh, even
|
||||
without the hardware in the workspace, that firmware *itself* could fall
|
||||
within ECCN 6A008 / USML XI(c), particularly if it implemented the
|
||||
matched-filter / coherent-array signal processing that distinguishes
|
||||
controlled radars from uncontrolled ones. We do not ship that firmware.
|
||||
|
||||
### 5.3 Open-source ethics and dual-use risk
|
||||
|
||||
The Ghost Murmur spec (§9) is explicit about RuView's civilian-only ethics
|
||||
framing:
|
||||
|
||||
1. Civilian, opt-in deployments only.
|
||||
2. No directional pursuit.
|
||||
3. Data minimisation.
|
||||
4. PII detection on the wire.
|
||||
5. Adversarial-signal detection.
|
||||
6. **No export-controlled hardware.**
|
||||
|
||||
Stand-off radar at 77 GHz with §95.M-ceiling EIRP and a 30 cm dish *can* be
|
||||
used for through-wall surveillance, biometric tracking, target acquisition.
|
||||
Sub-THz coherent radar can do the same with finer resolution. Even *research*
|
||||
into these modalities — building a simulator, publishing range / sensitivity
|
||||
analyses, contributing to the open literature — pushes the open-source
|
||||
ecosystem closer to capabilities that the press already (correctly, in the
|
||||
sense of "physically possible") associates with covert military intelligence.
|
||||
|
||||
Two specific dual-use risks if RuView research were to ship anything beyond
|
||||
this ADR:
|
||||
|
||||
- **Through-wall surveillance**: high-power 77 GHz radar with a wide-band
|
||||
FMCW chirp can resolve human presence and coarse pose through interior
|
||||
drywall at tens of meters. This is the literal Ghost Murmur use case at
|
||||
short range. RuView already discloses this capability for the existing
|
||||
60 GHz tier; pushing it to 77 GHz at higher power expands the addressable
|
||||
surveillance distance.
|
||||
- **Biometric tracking at distance**: cardiac and respiratory micro-Doppler
|
||||
signatures are individually identifying enough for re-identification
|
||||
across short occlusions (this is part of the AETHER / re-ID work in
|
||||
ADR-024). Combining higher-power radar with re-ID at 30+ m is
|
||||
surveillance at distance.
|
||||
- **Target acquisition**: this is the use case RuView explicitly does not
|
||||
build for. Period.
|
||||
|
||||
## 6. Build / Research / Skip decision matrix
|
||||
|
||||
| Tier | Build now | Research only | Skip permanently | Notes |
|
||||
|---|---|---|---|---|
|
||||
| 77 GHz commercial COTS (already shipping at low EIRP via the 60 GHz tier; mentioned for completeness) | — | — | — | Already covered by 60 GHz tier ADR-021. No action. |
|
||||
| 77 GHz higher-power experimental (≤ §95.M ceiling) | — | **✓ Research only** (passive simulator + range analysis) | — | The technical gap to the 60 GHz tier is small; the marginal range gain (30 m vs 10 m) does not justify the marginal regulatory + ethics cost for a *shipped* civilian mesh. Research / simulation only. |
|
||||
| 77 GHz beyond §95.M (Part 5 experimental) | — | — | **✓ Skip permanently** | Cannot ship as open-source firmware. Individual experimental licences are not delegatable. |
|
||||
| 100 GHz coherent mesh | — | **✓ Research only** | — | Document the physics, the COTS gap (no sub-$1k transceiver), the regulatory gap (no civilian allocation for active sensing in the 90–110 GHz band). Build only if all three conditions in §7.4 below trigger. |
|
||||
| 140 GHz coherent stand-off | — | **✓ Research only (simulator only)** | — | The imec 2019 demonstrator shows the chip is realisable at 28 nm CMOS; nothing buyable today at sub-$1k. ECCN 6A008 risk is real. Simulator OK; firmware no. |
|
||||
| 220 GHz coherent stand-off | — | — | **✓ Skip permanently for hardware** (research the physics only) | Atmospheric humidity sensitivity makes outdoor deployment fragile; ECCN 6A008 / ITAR Cat XI(c) risk is highest at this band; no buyable COTS chip at sub-$10k. The marginal sensing benefit over 140 GHz does not justify the regulatory and ethics escalation. |
|
||||
| 380+ GHz imaging | — | — | **✓ Skip permanently** | Imaging-band, not radar; humidity destroys outdoor link; export-controlled at any meaningful aperture. Not RuView's modality at any plausible build. |
|
||||
|
||||
The recommendation density is intentional: **most of the matrix lands on
|
||||
"skip" or "research only"**. Only one row (77 GHz at the §95.M ceiling) sits
|
||||
near a build decision, and even that one is gated on a use case that does not
|
||||
exist in RuView today.
|
||||
|
||||
## 7. If we research: what does RuView ship?
|
||||
|
||||
### 7.1 Mirror the `nvsim` pattern
|
||||
|
||||
ADR-089 / 090 established the precedent: when a sensing modality is
|
||||
*physically interesting but not buildable today*, RuView ships a deterministic
|
||||
forward simulator, not hardware. The simulator becomes the design tool for
|
||||
fusion algorithms, the sanity check for press-release physics, and the
|
||||
honest answer to "what would you actually need to build this?"
|
||||
|
||||
Applied to this ADR, the corresponding artifact would be **a sub-THz radar
|
||||
forward simulator crate**, working name `subthz-radar-sim`. Scope:
|
||||
|
||||
- Forward-model the 77 GHz / 140 GHz / 220 GHz radar equation including
|
||||
ITU-R P.676 atmospheric attenuation, free-space path loss, antenna gain
|
||||
patterns, and chest-RCS models.
|
||||
- Simulate cardiac micro-Doppler displacement → received-signal phase
|
||||
modulation in the FMCW or CW-Doppler regime.
|
||||
- Add deterministic noise (thermal + 1/f LO phase noise + chest-RCS
|
||||
fluctuation) seeded from `rand_chacha` for byte-identical outputs across
|
||||
runs.
|
||||
- Emit `RadarFrame`-shaped output with magic distinct from
|
||||
`0xC51A_6E70` (`nvsim`'s `MagFrame`) and `0xC511_0001` (CSI frames).
|
||||
- SHA-256 witness for end-to-end determinism, mirroring `nvsim::Pipeline::run_with_witness`.
|
||||
|
||||
### 7.2 Hard constraints on what the crate can ship
|
||||
|
||||
- **No firmware.** Not for ESP32, not for any SDR, not for any FPGA. The crate
|
||||
is host-side only. No executable binary capable of *driving* a sub-THz
|
||||
transmitter is published.
|
||||
- **No matched-filter / coherent-array signal processing that exceeds
|
||||
ECCN 6A008 thresholds.** The crate documents the physics and simulates the
|
||||
forward path. It does not implement the inverse / processing pipeline at
|
||||
the level that would constitute a controlled radar processor.
|
||||
- **No beamforming primitives for actively-steered phased arrays.** Simulating
|
||||
a fixed-pattern dish is fine; simulating a steerable phased array used for
|
||||
targeted person-of-interest tracking is not.
|
||||
- **No re-identification across the simulated radar stream.** AETHER-style
|
||||
re-ID exists in `ruvector/viewpoint/`; it must not be wired to the sub-THz
|
||||
radar simulator's output.
|
||||
- **Documented dual-use posture.** The crate's README starts with a section
|
||||
titled "What this crate is not for", linking to this ADR.
|
||||
|
||||
### 7.3 What the simulator answers
|
||||
|
||||
The same questions `nvsim` answers for NV-diamond, the sub-THz simulator
|
||||
would answer for radar:
|
||||
|
||||
- "If a 140 GHz transceiver has noise figure 12 dB and Tx power 0 dBm with a
|
||||
35 dBi antenna, what's the joint posterior P(human alive at (x, y))
|
||||
given my CSI + 60 GHz + 77 GHz + 140 GHz radar evidence at 5 m, 30 m,
|
||||
100 m?"
|
||||
- "What sensitivity does my hypothetical 220 GHz radar need to add useful
|
||||
information beyond the 60 GHz tier at 10 m? And does the answer change
|
||||
in 7.5 g/m³ humidity vs. 1 g/m³ dry air?"
|
||||
- "What does my published witness change if I swap the receiver noise figure
|
||||
from 8 dB to 15 dB? From 15 dB to 25 dB?"
|
||||
|
||||
These are pre-build sanity checks. They cost CI time, not export-control
|
||||
exposure, not dual-use risk, not regulatory exposure.
|
||||
|
||||
### 7.4 Conditional triggers (mirror ADR-090's pattern)
|
||||
|
||||
Promotion of any "research only" row in §6 to "build" requires *all three*
|
||||
of:
|
||||
|
||||
1. **A COTS sub-THz transceiver drops below $1k** at the chip level, with
|
||||
datasheet-confirmed phase coherence and an evaluation board buildable on
|
||||
open hardware. (Today: nothing.)
|
||||
2. **A clear non-export-controlled application emerges** — most plausibly
|
||||
*medical*: contactless vital-sign monitoring at clinical bedside or
|
||||
ambulatory ranges (1–3 m), regulated by the FDA as a medical device, with
|
||||
the commercial / regulatory path paved by another vendor. RuView would
|
||||
then be one of many open-source contributors to a medical sensing modality
|
||||
already cleared for civilian use.
|
||||
3. **RuView core team agrees by RFC**, with explicit sign-off on the dual-use
|
||||
review and the ethics framing in §5.3.
|
||||
|
||||
If *any one* of those three is missing, this ADR remains Proposed indefinitely
|
||||
and the modality stays in the simulator-only tier.
|
||||
|
||||
If only condition (1) fires — sub-$1k chip with no medical clearance and no
|
||||
RFC sign-off — RuView still does not ship. The simulator might be expanded;
|
||||
no firmware ships.
|
||||
|
||||
## 8. Related work / cross-references
|
||||
|
||||
### 8.1 ADRs
|
||||
|
||||
- **ADR-021** — Vital-sign detection via 60 GHz mmWave + WiFi CSI. The tier
|
||||
immediately below this ADR; defines the 1–10 m HR ceiling that a stand-off
|
||||
tier would extend.
|
||||
- **ADR-029** — RuvSense multistatic sensing mode. Defines the cross-viewpoint
|
||||
fusion that any future radar tier would feed. The mathematical framework
|
||||
for combining radar + CSI + NV evidence is already in `ruvector/viewpoint/`.
|
||||
- **ADR-089** — `nvsim` NV-diamond pipeline simulator. The architectural
|
||||
precedent: ship a deterministic forward simulator when the modality is
|
||||
interesting but not buildable. Same proof / witness pattern applies here.
|
||||
- **ADR-090** — `nvsim` Lindblad / Hamiltonian extension. Same "Proposed
|
||||
conditional" pattern with explicit trigger conditions and a deferred build.
|
||||
This ADR follows the same shape.
|
||||
- **ADR-040** — PII detection gates. Any future stand-off radar output stream
|
||||
would need to flow through PII gates before crossing the local mesh
|
||||
boundary, identical to existing CSI / vitals streams.
|
||||
- **ADR-024** — AETHER contrastive embedding. Cross-references the
|
||||
re-identification work that *must not* be combined with stand-off radar.
|
||||
- **ADR-028** — ESP32 capability audit + witness verification. The
|
||||
deterministic-witness pattern applies to any new simulator crate.
|
||||
|
||||
### 8.2 Research docs
|
||||
|
||||
- `docs/research/quantum-sensing/16-ghost-murmur-ruview-spec.md` — the
|
||||
Ghost Murmur reality-check spec. §6.3 is the explicit boundary that
|
||||
triggered this ADR. §7–§9 establish the architecture, ethics, and legal
|
||||
framework that this ADR inherits.
|
||||
|
||||
### 8.3 Primary literature (radar at 24 / 77 / 120–140 GHz)
|
||||
|
||||
- **Massagram, W., Lubecke, V. M., Høst-Madsen, A., Boric-Lubecke, O.
|
||||
(2013).** "Parametric Study of Antennas for Long Range Doppler Radar
|
||||
Heart Rate Detection." *IEEE EMBC* 2013.
|
||||
([PMC4900816](https://pmc.ncbi.nlm.nih.gov/articles/PMC4900816/))
|
||||
— HR @ 21 m, respiration @ 69 m at 24 GHz CW.
|
||||
- **Mostafanezhad, I., Boric-Lubecke, O. (2014).** "Benefits of Coherent
|
||||
Low-IF for Vital Signs Monitoring." *IEEE Microw. Wireless Compon. Lett.*
|
||||
24(10), 711–713.
|
||||
- **Adib, F. et al. (2015).** "Smart Homes that Monitor Breathing and Heart
|
||||
Rate." *Proc. CHI 2015*. Short-range through-wall.
|
||||
- **Wang, G. et al. (2020).** "Remote Monitoring of Human Vital Signs Based
|
||||
on 77-GHz mm-Wave FMCW Radar." *Sensors* 20(10), 2999.
|
||||
([PMC7285495](https://pmc.ncbi.nlm.nih.gov/articles/PMC7285495/))
|
||||
- **Liu, J. et al. (2022).** "Real-Time Heart Rate Detection Method Based on
|
||||
77 GHz FMCW Radar." *Micromachines* 13(11), 1960.
|
||||
([PMC9693980](https://pmc.ncbi.nlm.nih.gov/articles/PMC9693980/))
|
||||
- **Chen, J. et al. (2024).** "Contactless and Short-Range Vital Signs
|
||||
Detection with Doppler Radar Millimetre-Wave (76–81 GHz) Sensing Firmware."
|
||||
*Healthcare Technology Letters* 11.
|
||||
([Wiley HTL](https://ietresearch.onlinelibrary.wiley.com/doi/full/10.1049/htl2.12075))
|
||||
- **Iyer, S. et al. (2022).** "mm-Wave Radar-Based Vital Signs Monitoring
|
||||
and Arrhythmia Detection Using Machine Learning." *Sensors*.
|
||||
([PMC9104941](https://pmc.ncbi.nlm.nih.gov/articles/PMC9104941/))
|
||||
|
||||
### 8.4 Primary literature (sub-THz)
|
||||
|
||||
- **imec / Peeters et al. (2019).** Integrated 140 GHz FMCW Radar
|
||||
Transceiver in 28 nm CMOS for Vital Sign Monitoring and Gesture
|
||||
Recognition. *Microwave Journal* 2019-06-09; imec magazine May 2019.
|
||||
([Microwave Journal](https://www.microwavejournal.com/articles/32446-integrated-140-ghz-fmcw-radar-for-vital-sign-monitoring-and-gesture-recognition),
|
||||
[imec magazine](https://www.imec-int.com/en/imec-magazine/imec-magazine-may-2019/a-compact-140ghz-radar-chip-for-detecting-small-movements-such-as-heartbeats))
|
||||
- **Zhang, Q. et al. (2021).** "Non-Contact Monitoring of Human Vital
|
||||
Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band." *Sensors*
|
||||
21. ([PMC8070581](https://pmc.ncbi.nlm.nih.gov/articles/PMC8070581/))
|
||||
- **Yamagishi, H. et al. (2022).** "A new principle of pulse detection
|
||||
based on terahertz wave plethysmography." *Scientific Reports* 12,
|
||||
2022. ([Nature SREP](https://www.nature.com/articles/s41598-022-09801-w))
|
||||
- ITU-R Recommendation **P.676-11** (2016). "Attenuation by atmospheric
|
||||
gases." International Telecommunication Union.
|
||||
([P.676-11 PDF](https://www.itu.int/dms_pubrec/itu-r/rec/p/R-REC-P.676-11-201609-I!!PDF-E.pdf))
|
||||
- 47 CFR Part 95 Subpart M — The 76–81 GHz Band Radar Service.
|
||||
([eCFR](https://www.ecfr.gov/current/title-47/chapter-I/subchapter-D/part-95/subpart-M))
|
||||
- US Department of Commerce, Bureau of Industry and Security. **Commerce
|
||||
Control List Category 6 — Sensors and Lasers**, ECCN 6A008.
|
||||
([BIS CCL Cat. 6](https://www.bis.doc.gov/index.php/documents/regulations-docs/2340-ccl9-4/file))
|
||||
|
||||
### 8.5 Reviews
|
||||
|
||||
- **Li, C. et al. (2024).** "Radar-Based Heart Cardiac Activity Measurements:
|
||||
A Review." *Sensors*. ([PMC11645089](https://pmc.ncbi.nlm.nih.gov/articles/PMC11645089/))
|
||||
- **Frontiers in Physiology (2022).** "Radar-based remote physiological
|
||||
sensing: Progress, challenges, and opportunities."
|
||||
([Frontiers](https://www.frontiersin.org/journals/physiology/articles/10.3389/fphys.2022.955208/full))
|
||||
|
||||
## 9. Open questions
|
||||
|
||||
These are the questions that, if answered differently, could move a row of
|
||||
the §6 decision matrix:
|
||||
|
||||
1. **Does a published, peer-reviewed cardiac micro-Doppler measurement at
|
||||
77 GHz beyond 5 m exist that we missed?** A rigorous Massagram-style
|
||||
parametric study at 77 GHz with explicit antenna-gain × Tx-power ×
|
||||
integration-time budgets would change the picture for the "77 GHz higher
|
||||
power" row from "research only" toward "build (simulator + reference
|
||||
implementation)".
|
||||
2. **Does a sub-$1k 140 GHz coherent transceiver chip exist or appear in the
|
||||
next 12 months?** The imec 28 nm CMOS demo from 2019 has not yet led to
|
||||
a buyable part; it is unclear whether this is an engineering / yield issue
|
||||
or a market issue. If a part appears, condition (1) of §7.4 fires.
|
||||
3. **Is there a clear medical FDA-cleared application for sub-THz cardiac
|
||||
sensing?** This is the single most important gating condition. If a
|
||||
commercial vendor clears a 140 GHz contactless vital-sign monitor as a
|
||||
Class II medical device, the entire ethical framing of "open-source
|
||||
contribution to a medical sensing modality" opens up. Without that
|
||||
clearance, RuView remains in the simulator-only tier.
|
||||
4. **Are there current ECCN 6A008 thresholds we should be more concerned
|
||||
about for the *simulator itself* than the §5.2 analysis suggests?** The
|
||||
simulator is forward-only and emits IQ samples and a SHA-256 witness.
|
||||
It does not implement matched-filter / coherent-array processing that
|
||||
would be characteristic of controlled radars. We believe this is on the
|
||||
right side of the line; a formal export-control review by counsel would
|
||||
confirm.
|
||||
5. **Should RuView contribute the sub-THz simulator to a neutral upstream**
|
||||
(e.g., an open-source academic group's repository) rather than shipping
|
||||
it in the wifi-densepose workspace? Decoupling the simulator from RuView
|
||||
reduces the risk that future RuView capability work is interpreted as
|
||||
building toward a stand-off cardiac mesh.
|
||||
6. **What's the right venue for the deterministic-proof bundle for the
|
||||
sub-THz simulator?** Same question that ADR-089 left open. Probably
|
||||
the same answer: in-tree fixture + tagged release artifact.
|
||||
|
||||
## 10. Decision summary
|
||||
|
||||
This ADR is **Proposed — Research only**. The decision matrix in §6 lands on:
|
||||
|
||||
- **Skip permanently**: 77 GHz beyond §95.M, 220 GHz coherent stand-off
|
||||
hardware, 380+ GHz imaging.
|
||||
- **Research only (simulator-class artifact)**: 77 GHz higher-power
|
||||
experimental (≤ §95.M ceiling), 100 GHz coherent mesh, 140 GHz coherent
|
||||
stand-off.
|
||||
- **Build now**: nothing.
|
||||
|
||||
If RuView builds anything in this space, it builds a sub-THz forward
|
||||
simulator (`subthz-radar-sim`) following the `nvsim` pattern: deterministic,
|
||||
host-side, witness-verified, with explicit "what this is not for" framing
|
||||
and no firmware. The simulator does not ship until conditions §7.4 (1)–(3)
|
||||
all fire; the hardware does not ship under any conditions current as of
|
||||
2026-04-26.
|
||||
|
||||
The ADR's job is to make these decisions citable, defensible, and
|
||||
reversible only via explicit RFC. It is not a build commitment.
|
||||
Loading…
Reference in New Issue